• NASA Portal
  • Site Help
  • Feedback
  • Phone Book
Search For:
in
  • HOME
  • OVERVIEW
  • DATA
  • ANNEX
  • DOCUMENTS
  • SOFTWARE
  • PERSONNEL
  • RELATED SITES
  • ABOUT PDS
 
  • Instrument
  • Missions
  • Target/Planet
  • Volume Series
  • Errata

QUICK SEARCH

Search By Missions

QUICK LINKS

FAQ
Citation Policy
Errata for all volumes
Help for Data Users
Help for Data Reviewers
Help for Data Providers

PDS NODES

PDS Home
Atmospheres
Geosciences
Cartography and Imaging Sciences
NAIF - SPICE
Ring-Moon Systems
Small Bodies
Cassini >> MIMI
CASSINI SATURN MIMI LEMMS CALIBRATED DATA ARCHIVE View Errata Order Volume Toggle viewing into expanded mode
CO-S-MIMI-4-LEMMS-CALIB-V1.0 PDS 3      CERTIFIED
Start Time: 2004-01-01 08:00:00 - Stop Time: 2017-09-16 10:00:00
CASSINI SATURN MIMI LEMMS CALIBRATED DATA ARCHIVE
CASSINI SATURN MIMI LEMMS CALIBRATED DATA ARCHIVE
Citiation Information
Author Vandegriff J., Kusterer M.B.
TitleCASSINI SATURN MIMI LEMMS CALIBRATED DATA ARCHIVE
PublisherNASA Planetary Data System
Publication Year 2018
doi https://doi.org/10.17189/1519608
Top/ DATA/ LPHAAVG0_1MIN/ 2008 / click here to download folders and files
LPHAAVG0_1MIN_2008001_01
Start Time: 2008-001T00:00 Stop Time: 2008-002T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008002_01
Start Time: 2008-002T00:00 Stop Time: 2008-003T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008003_01
Start Time: 2008-003T00:00 Stop Time: 2008-004T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008004_01
Start Time: 2008-004T00:00 Stop Time: 2008-005T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008005_01
Start Time: 2008-005T00:00 Stop Time: 2008-006T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008006_01
Start Time: 2008-006T00:00 Stop Time: 2008-007T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008007_01
Start Time: 2008-007T00:00 Stop Time: 2008-008T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008008_01
Start Time: 2008-008T00:00 Stop Time: 2008-009T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008009_01
Start Time: 2008-009T00:00 Stop Time: 2008-010T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008010_01
Start Time: 2008-010T00:00 Stop Time: 2008-011T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008011_01
Start Time: 2008-011T00:00 Stop Time: 2008-012T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008012_01
Start Time: 2008-012T00:00 Stop Time: 2008-013T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008013_01
Start Time: 2008-013T00:00 Stop Time: 2008-014T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008014_01
Start Time: 2008-014T00:00 Stop Time: 2008-015T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008015_01
Start Time: 2008-015T00:00 Stop Time: 2008-016T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008016_01
Start Time: 2008-016T00:00 Stop Time: 2008-017T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008017_01
Start Time: 2008-017T00:00 Stop Time: 2008-018T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008018_01
Start Time: 2008-018T00:00 Stop Time: 2008-019T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008019_01
Start Time: 2008-019T00:00 Stop Time: 2008-020T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008020_01
Start Time: 2008-020T00:00 Stop Time: 2008-021T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008021_01
Start Time: 2008-021T00:00 Stop Time: 2008-022T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008022_01
Start Time: 2008-022T00:00 Stop Time: 2008-023T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008023_01
Start Time: 2008-023T00:00 Stop Time: 2008-024T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008024_01
Start Time: 2008-024T00:00 Stop Time: 2008-025T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008025_01
Start Time: 2008-025T00:00 Stop Time: 2008-026T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008026_01
Start Time: 2008-026T00:00 Stop Time: 2008-027T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008027_01
Start Time: 2008-027T00:00 Stop Time: 2008-028T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008028_01
Start Time: 2008-028T00:00 Stop Time: 2008-029T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008029_01
Start Time: 2008-029T00:00 Stop Time: 2008-030T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008030_01
Start Time: 2008-030T00:00 Stop Time: 2008-031T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008031_01
Start Time: 2008-031T00:00 Stop Time: 2008-032T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008032_01
Start Time: 2008-032T00:00 Stop Time: 2008-033T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008033_01
Start Time: 2008-033T00:00 Stop Time: 2008-034T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008034_01
Start Time: 2008-034T00:00 Stop Time: 2008-035T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008035_01
Start Time: 2008-035T00:00 Stop Time: 2008-036T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008036_01
Start Time: 2008-036T00:00 Stop Time: 2008-037T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008037_01
Start Time: 2008-037T00:00 Stop Time: 2008-038T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008038_01
Start Time: 2008-038T00:00 Stop Time: 2008-039T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008039_01
Start Time: 2008-039T00:00 Stop Time: 2008-040T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008040_01
Start Time: 2008-040T00:00 Stop Time: 2008-041T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008041_01
Start Time: 2008-041T00:00 Stop Time: 2008-042T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008042_01
Start Time: 2008-042T00:00 Stop Time: 2008-043T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008043_01
Start Time: 2008-043T00:00 Stop Time: 2008-044T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008044_01
Start Time: 2008-044T00:00 Stop Time: 2008-045T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008045_01
Start Time: 2008-045T00:00 Stop Time: 2008-046T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008046_01
Start Time: 2008-046T00:00 Stop Time: 2008-047T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008047_01
Start Time: 2008-047T00:00 Stop Time: 2008-048T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008048_01
Start Time: 2008-048T00:00 Stop Time: 2008-049T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008049_01
Start Time: 2008-049T00:00 Stop Time: 2008-050T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008050_01
Start Time: 2008-050T00:00 Stop Time: 2008-051T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008051_01
Start Time: 2008-051T00:00 Stop Time: 2008-052T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008052_01
Start Time: 2008-052T00:00 Stop Time: 2008-053T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008053_01
Start Time: 2008-053T00:00 Stop Time: 2008-054T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008054_01
Start Time: 2008-054T00:00 Stop Time: 2008-055T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008055_01
Start Time: 2008-055T00:00 Stop Time: 2008-056T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008056_01
Start Time: 2008-056T00:00 Stop Time: 2008-057T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008057_01
Start Time: 2008-057T00:00 Stop Time: 2008-058T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008058_01
Start Time: 2008-058T00:00 Stop Time: 2008-059T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008059_01
Start Time: 2008-059T00:00 Stop Time: 2008-060T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008060_01
Start Time: 2008-060T00:00 Stop Time: 2008-061T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008061_01
Start Time: 2008-061T00:00 Stop Time: 2008-062T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008062_01
Start Time: 2008-062T00:00 Stop Time: 2008-063T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008063_01
Start Time: 2008-063T00:00 Stop Time: 2008-064T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008064_01
Start Time: 2008-064T00:00 Stop Time: 2008-065T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008065_01
Start Time: 2008-065T00:00 Stop Time: 2008-066T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008066_01
Start Time: 2008-066T00:00 Stop Time: 2008-067T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008067_01
Start Time: 2008-067T00:00 Stop Time: 2008-068T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008068_01
Start Time: 2008-068T00:00 Stop Time: 2008-069T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008069_01
Start Time: 2008-069T00:00 Stop Time: 2008-070T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008070_01
Start Time: 2008-070T00:00 Stop Time: 2008-071T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008071_01
Start Time: 2008-071T00:00 Stop Time: 2008-072T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008072_01
Start Time: 2008-072T00:00 Stop Time: 2008-073T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008073_01
Start Time: 2008-073T00:00 Stop Time: 2008-074T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008074_01
Start Time: 2008-074T00:00 Stop Time: 2008-075T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008075_01
Start Time: 2008-075T00:00 Stop Time: 2008-076T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008076_01
Start Time: 2008-076T00:00 Stop Time: 2008-077T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008077_01
Start Time: 2008-077T00:00 Stop Time: 2008-078T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008078_01
Start Time: 2008-078T00:00 Stop Time: 2008-079T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008079_01
Start Time: 2008-079T00:00 Stop Time: 2008-080T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008080_01
Start Time: 2008-080T00:00 Stop Time: 2008-081T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008081_01
Start Time: 2008-081T00:00 Stop Time: 2008-082T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008082_01
Start Time: 2008-082T00:00 Stop Time: 2008-083T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008083_01
Start Time: 2008-083T00:00 Stop Time: 2008-084T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008084_01
Start Time: 2008-084T00:00 Stop Time: 2008-085T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008085_01
Start Time: 2008-085T00:00 Stop Time: 2008-086T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008086_01
Start Time: 2008-086T00:00 Stop Time: 2008-087T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008087_01
Start Time: 2008-087T00:00 Stop Time: 2008-088T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008088_01
Start Time: 2008-088T00:00 Stop Time: 2008-089T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008089_01
Start Time: 2008-089T00:00 Stop Time: 2008-090T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008090_01
Start Time: 2008-090T00:00 Stop Time: 2008-091T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008091_01
Start Time: 2008-091T00:00 Stop Time: 2008-092T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008092_01
Start Time: 2008-092T00:00 Stop Time: 2008-093T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008093_01
Start Time: 2008-093T00:00 Stop Time: 2008-094T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008094_01
Start Time: 2008-094T00:00 Stop Time: 2008-095T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008095_01
Start Time: 2008-095T00:00 Stop Time: 2008-096T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008096_01
Start Time: 2008-096T00:00 Stop Time: 2008-097T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008097_01
Start Time: 2008-097T00:00 Stop Time: 2008-098T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008098_01
Start Time: 2008-098T00:00 Stop Time: 2008-099T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008099_01
Start Time: 2008-099T00:00 Stop Time: 2008-100T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008100_01
Start Time: 2008-100T00:00 Stop Time: 2008-101T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008101_01
Start Time: 2008-101T00:00 Stop Time: 2008-102T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008102_01
Start Time: 2008-102T00:00 Stop Time: 2008-103T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008103_01
Start Time: 2008-103T00:00 Stop Time: 2008-104T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008104_01
Start Time: 2008-104T00:00 Stop Time: 2008-105T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008105_01
Start Time: 2008-105T00:00 Stop Time: 2008-106T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008106_01
Start Time: 2008-106T00:00 Stop Time: 2008-107T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008107_01
Start Time: 2008-107T00:00 Stop Time: 2008-108T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008108_01
Start Time: 2008-108T00:00 Stop Time: 2008-109T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008109_01
Start Time: 2008-109T00:00 Stop Time: 2008-110T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008110_01
Start Time: 2008-110T00:00 Stop Time: 2008-111T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008111_01
Start Time: 2008-111T00:00 Stop Time: 2008-112T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008112_01
Start Time: 2008-112T00:00 Stop Time: 2008-113T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008113_01
Start Time: 2008-113T00:00 Stop Time: 2008-114T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008114_01
Start Time: 2008-114T00:00 Stop Time: 2008-115T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008115_01
Start Time: 2008-115T00:00 Stop Time: 2008-116T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008116_01
Start Time: 2008-116T00:00 Stop Time: 2008-117T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008117_01
Start Time: 2008-117T00:00 Stop Time: 2008-118T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008118_01
Start Time: 2008-118T00:00 Stop Time: 2008-119T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008119_01
Start Time: 2008-119T00:00 Stop Time: 2008-120T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008120_01
Start Time: 2008-120T00:00 Stop Time: 2008-121T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008121_01
Start Time: 2008-121T00:00 Stop Time: 2008-122T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008122_01
Start Time: 2008-122T00:00 Stop Time: 2008-123T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008123_01
Start Time: 2008-123T00:00 Stop Time: 2008-124T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008124_01
Start Time: 2008-124T00:00 Stop Time: 2008-125T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008125_01
Start Time: 2008-125T00:00 Stop Time: 2008-126T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008126_01
Start Time: 2008-126T00:00 Stop Time: 2008-127T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008127_01
Start Time: 2008-127T00:00 Stop Time: 2008-128T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008128_01
Start Time: 2008-128T00:00 Stop Time: 2008-129T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008129_01
Start Time: 2008-129T00:00 Stop Time: 2008-130T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008130_01
Start Time: 2008-130T00:00 Stop Time: 2008-131T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008131_01
Start Time: 2008-131T00:00 Stop Time: 2008-132T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008132_01
Start Time: 2008-132T00:00 Stop Time: 2008-133T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008133_01
Start Time: 2008-133T00:00 Stop Time: 2008-134T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008134_01
Start Time: 2008-134T00:00 Stop Time: 2008-135T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008135_01
Start Time: 2008-135T00:00 Stop Time: 2008-136T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008136_01
Start Time: 2008-136T00:00 Stop Time: 2008-137T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008137_01
Start Time: 2008-137T00:00 Stop Time: 2008-138T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008138_01
Start Time: 2008-138T00:00 Stop Time: 2008-139T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008139_01
Start Time: 2008-139T00:00 Stop Time: 2008-140T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008140_01
Start Time: 2008-140T00:00 Stop Time: 2008-141T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008141_01
Start Time: 2008-141T00:00 Stop Time: 2008-142T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008142_01
Start Time: 2008-142T00:00 Stop Time: 2008-143T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008143_01
Start Time: 2008-143T00:00 Stop Time: 2008-144T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008144_01
Start Time: 2008-144T00:00 Stop Time: 2008-145T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008145_01
Start Time: 2008-145T00:00 Stop Time: 2008-146T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008146_01
Start Time: 2008-146T00:00 Stop Time: 2008-147T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008147_01
Start Time: 2008-147T00:00 Stop Time: 2008-148T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008148_01
Start Time: 2008-148T00:00 Stop Time: 2008-149T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008149_01
Start Time: 2008-149T00:00 Stop Time: 2008-150T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008150_01
Start Time: 2008-150T00:00 Stop Time: 2008-151T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008151_01
Start Time: 2008-151T00:00 Stop Time: 2008-152T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008152_01
Start Time: 2008-152T00:00 Stop Time: 2008-153T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008153_01
Start Time: 2008-153T00:00 Stop Time: 2008-154T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008154_01
Start Time: 2008-154T00:00 Stop Time: 2008-155T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008155_01
Start Time: 2008-155T00:00 Stop Time: 2008-156T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008156_01
Start Time: 2008-156T00:00 Stop Time: 2008-157T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008157_01
Start Time: 2008-157T00:00 Stop Time: 2008-158T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008158_01
Start Time: 2008-158T00:00 Stop Time: 2008-159T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008159_01
Start Time: 2008-159T00:00 Stop Time: 2008-160T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008160_01
Start Time: 2008-160T00:00 Stop Time: 2008-161T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008161_01
Start Time: 2008-161T00:00 Stop Time: 2008-162T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008162_01
Start Time: 2008-162T00:00 Stop Time: 2008-163T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008163_01
Start Time: 2008-163T00:00 Stop Time: 2008-164T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008164_01
Start Time: 2008-164T00:00 Stop Time: 2008-165T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008165_01
Start Time: 2008-165T00:00 Stop Time: 2008-166T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008166_01
Start Time: 2008-166T00:00 Stop Time: 2008-167T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008167_01
Start Time: 2008-167T00:00 Stop Time: 2008-168T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008168_01
Start Time: 2008-168T00:00 Stop Time: 2008-169T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008169_01
Start Time: 2008-169T00:00 Stop Time: 2008-170T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008170_01
Start Time: 2008-170T00:00 Stop Time: 2008-171T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008171_01
Start Time: 2008-171T00:00 Stop Time: 2008-172T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008172_01
Start Time: 2008-172T00:00 Stop Time: 2008-173T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008173_01
Start Time: 2008-173T00:00 Stop Time: 2008-174T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008174_01
Start Time: 2008-174T00:00 Stop Time: 2008-175T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008175_01
Start Time: 2008-175T00:00 Stop Time: 2008-176T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008176_01
Start Time: 2008-176T00:00 Stop Time: 2008-177T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008177_01
Start Time: 2008-177T00:00 Stop Time: 2008-178T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008178_01
Start Time: 2008-178T00:00 Stop Time: 2008-179T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008179_01
Start Time: 2008-179T00:00 Stop Time: 2008-180T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008180_01
Start Time: 2008-180T00:00 Stop Time: 2008-181T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008181_01
Start Time: 2008-181T00:00 Stop Time: 2008-182T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008182_01
Start Time: 2008-182T00:00 Stop Time: 2008-183T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008183_01
Start Time: 2008-183T00:00 Stop Time: 2008-184T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008184_01
Start Time: 2008-184T00:00 Stop Time: 2008-185T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008185_01
Start Time: 2008-185T00:00 Stop Time: 2008-186T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008186_01
Start Time: 2008-186T00:00 Stop Time: 2008-187T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008187_01
Start Time: 2008-187T00:00 Stop Time: 2008-188T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008188_01
Start Time: 2008-188T00:00 Stop Time: 2008-189T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008189_01
Start Time: 2008-189T00:00 Stop Time: 2008-190T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008190_01
Start Time: 2008-190T00:00 Stop Time: 2008-191T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008191_01
Start Time: 2008-191T00:00 Stop Time: 2008-192T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008192_01
Start Time: 2008-192T00:00 Stop Time: 2008-193T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008193_01
Start Time: 2008-193T00:00 Stop Time: 2008-194T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008194_01
Start Time: 2008-194T00:00 Stop Time: 2008-195T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008195_01
Start Time: 2008-195T00:00 Stop Time: 2008-196T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008196_01
Start Time: 2008-196T00:00 Stop Time: 2008-197T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008197_01
Start Time: 2008-197T00:00 Stop Time: 2008-198T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008198_01
Start Time: 2008-198T00:00 Stop Time: 2008-199T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008199_01
Start Time: 2008-199T00:00 Stop Time: 2008-200T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008200_01
Start Time: 2008-200T00:00 Stop Time: 2008-201T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008201_01
Start Time: 2008-201T00:00 Stop Time: 2008-202T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008202_01
Start Time: 2008-202T00:00 Stop Time: 2008-203T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008203_01
Start Time: 2008-203T00:00 Stop Time: 2008-204T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008204_01
Start Time: 2008-204T00:00 Stop Time: 2008-205T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008205_01
Start Time: 2008-205T00:00 Stop Time: 2008-206T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008206_01
Start Time: 2008-206T00:00 Stop Time: 2008-207T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008207_01
Start Time: 2008-207T00:00 Stop Time: 2008-208T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008208_01
Start Time: 2008-208T00:00 Stop Time: 2008-209T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008209_01
Start Time: 2008-209T00:00 Stop Time: 2008-210T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008210_01
Start Time: 2008-210T00:00 Stop Time: 2008-211T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008211_01
Start Time: 2008-211T00:00 Stop Time: 2008-212T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008212_01
Start Time: 2008-212T00:00 Stop Time: 2008-213T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008213_01
Start Time: 2008-213T00:00 Stop Time: 2008-214T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008214_01
Start Time: 2008-214T00:00 Stop Time: 2008-215T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008215_01
Start Time: 2008-215T00:00 Stop Time: 2008-216T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008216_01
Start Time: 2008-216T00:00 Stop Time: 2008-217T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008217_01
Start Time: 2008-217T00:00 Stop Time: 2008-218T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008218_01
Start Time: 2008-218T00:00 Stop Time: 2008-219T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008219_01
Start Time: 2008-219T00:00 Stop Time: 2008-220T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008220_01
Start Time: 2008-220T00:00 Stop Time: 2008-221T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008221_01
Start Time: 2008-221T00:00 Stop Time: 2008-222T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008222_01
Start Time: 2008-222T00:00 Stop Time: 2008-223T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008223_01
Start Time: 2008-223T00:00 Stop Time: 2008-224T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008224_01
Start Time: 2008-224T00:00 Stop Time: 2008-225T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008225_01
Start Time: 2008-225T00:00 Stop Time: 2008-226T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008226_01
Start Time: 2008-226T00:00 Stop Time: 2008-227T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008227_01
Start Time: 2008-227T00:00 Stop Time: 2008-228T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008228_01
Start Time: 2008-228T00:00 Stop Time: 2008-229T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008229_01
Start Time: 2008-229T00:00 Stop Time: 2008-230T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008230_01
Start Time: 2008-230T00:00 Stop Time: 2008-231T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008231_01
Start Time: 2008-231T00:00 Stop Time: 2008-232T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008232_01
Start Time: 2008-232T00:00 Stop Time: 2008-233T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008233_01
Start Time: 2008-233T00:00 Stop Time: 2008-234T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008234_01
Start Time: 2008-234T00:00 Stop Time: 2008-235T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008235_01
Start Time: 2008-235T00:00 Stop Time: 2008-236T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008236_01
Start Time: 2008-236T00:00 Stop Time: 2008-237T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008237_01
Start Time: 2008-237T00:00 Stop Time: 2008-238T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008238_01
Start Time: 2008-238T00:00 Stop Time: 2008-239T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008239_01
Start Time: 2008-239T00:00 Stop Time: 2008-240T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008240_01
Start Time: 2008-240T00:00 Stop Time: 2008-241T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008241_01
Start Time: 2008-241T00:00 Stop Time: 2008-242T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008242_01
Start Time: 2008-242T00:00 Stop Time: 2008-243T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008243_01
Start Time: 2008-243T00:00 Stop Time: 2008-244T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008244_01
Start Time: 2008-244T00:00 Stop Time: 2008-245T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008245_01
Start Time: 2008-245T00:00 Stop Time: 2008-246T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008246_01
Start Time: 2008-246T00:00 Stop Time: 2008-247T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008247_01
Start Time: 2008-247T00:00 Stop Time: 2008-248T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008248_01
Start Time: 2008-248T00:00 Stop Time: 2008-249T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008249_01
Start Time: 2008-249T00:00 Stop Time: 2008-250T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008250_01
Start Time: 2008-250T00:00 Stop Time: 2008-251T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008251_01
Start Time: 2008-251T00:00 Stop Time: 2008-252T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008252_01
Start Time: 2008-252T00:00 Stop Time: 2008-253T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008253_01
Start Time: 2008-253T00:00 Stop Time: 2008-254T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008254_01
Start Time: 2008-254T00:00 Stop Time: 2008-255T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008255_01
Start Time: 2008-255T00:00 Stop Time: 2008-256T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008256_01
Start Time: 2008-256T00:00 Stop Time: 2008-257T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008257_01
Start Time: 2008-257T00:00 Stop Time: 2008-258T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008258_01
Start Time: 2008-258T00:00 Stop Time: 2008-259T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008259_01
Start Time: 2008-259T00:00 Stop Time: 2008-260T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008260_01
Start Time: 2008-260T00:00 Stop Time: 2008-261T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008261_01
Start Time: 2008-261T00:00 Stop Time: 2008-262T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008262_01
Start Time: 2008-262T00:00 Stop Time: 2008-263T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008263_01
Start Time: 2008-263T00:00 Stop Time: 2008-264T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008264_01
Start Time: 2008-264T00:00 Stop Time: 2008-265T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008265_01
Start Time: 2008-265T00:00 Stop Time: 2008-266T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008266_01
Start Time: 2008-266T00:00 Stop Time: 2008-267T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008267_01
Start Time: 2008-267T00:00 Stop Time: 2008-268T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008268_01
Start Time: 2008-268T00:00 Stop Time: 2008-269T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008269_01
Start Time: 2008-269T00:00 Stop Time: 2008-270T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008270_01
Start Time: 2008-270T00:00 Stop Time: 2008-271T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008271_01
Start Time: 2008-271T00:00 Stop Time: 2008-272T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008272_01
Start Time: 2008-272T00:00 Stop Time: 2008-273T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008273_01
Start Time: 2008-273T00:00 Stop Time: 2008-274T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008274_01
Start Time: 2008-274T00:00 Stop Time: 2008-275T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008275_01
Start Time: 2008-275T00:00 Stop Time: 2008-276T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008276_01
Start Time: 2008-276T00:00 Stop Time: 2008-277T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008277_01
Start Time: 2008-277T00:00 Stop Time: 2008-278T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008278_01
Start Time: 2008-278T00:00 Stop Time: 2008-279T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008279_01
Start Time: 2008-279T00:00 Stop Time: 2008-280T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008280_01
Start Time: 2008-280T00:00 Stop Time: 2008-281T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008281_01
Start Time: 2008-281T00:00 Stop Time: 2008-282T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008282_01
Start Time: 2008-282T00:00 Stop Time: 2008-283T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008283_01
Start Time: 2008-283T00:00 Stop Time: 2008-284T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008284_01
Start Time: 2008-284T00:00 Stop Time: 2008-285T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008285_01
Start Time: 2008-285T00:00 Stop Time: 2008-286T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008286_01
Start Time: 2008-286T00:00 Stop Time: 2008-287T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008287_01
Start Time: 2008-287T00:00 Stop Time: 2008-288T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008288_01
Start Time: 2008-288T00:00 Stop Time: 2008-289T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008289_01
Start Time: 2008-289T00:00 Stop Time: 2008-290T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008290_01
Start Time: 2008-290T00:00 Stop Time: 2008-291T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008291_01
Start Time: 2008-291T00:00 Stop Time: 2008-292T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008292_01
Start Time: 2008-292T00:00 Stop Time: 2008-293T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008293_01
Start Time: 2008-293T00:00 Stop Time: 2008-294T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008294_01
Start Time: 2008-294T00:00 Stop Time: 2008-295T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008295_01
Start Time: 2008-295T00:00 Stop Time: 2008-296T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008296_01
Start Time: 2008-296T00:00 Stop Time: 2008-297T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008297_01
Start Time: 2008-297T00:00 Stop Time: 2008-298T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008298_01
Start Time: 2008-298T00:00 Stop Time: 2008-299T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008299_01
Start Time: 2008-299T00:00 Stop Time: 2008-300T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008300_01
Start Time: 2008-300T00:00 Stop Time: 2008-301T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008301_01
Start Time: 2008-301T00:00 Stop Time: 2008-302T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008302_01
Start Time: 2008-302T00:00 Stop Time: 2008-303T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008303_01
Start Time: 2008-303T00:00 Stop Time: 2008-304T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008304_01
Start Time: 2008-304T00:00 Stop Time: 2008-305T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008305_01
Start Time: 2008-305T00:00 Stop Time: 2008-306T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008306_01
Start Time: 2008-306T00:00 Stop Time: 2008-307T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008307_01
Start Time: 2008-307T00:00 Stop Time: 2008-308T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008308_01
Start Time: 2008-308T00:00 Stop Time: 2008-309T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008309_01
Start Time: 2008-309T00:00 Stop Time: 2008-310T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008310_01
Start Time: 2008-310T00:00 Stop Time: 2008-311T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008311_01
Start Time: 2008-311T00:00 Stop Time: 2008-312T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008312_01
Start Time: 2008-312T00:00 Stop Time: 2008-313T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008313_01
Start Time: 2008-313T00:00 Stop Time: 2008-314T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008314_01
Start Time: 2008-314T00:00 Stop Time: 2008-315T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008315_01
Start Time: 2008-315T00:00 Stop Time: 2008-316T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008316_01
Start Time: 2008-316T00:00 Stop Time: 2008-317T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008317_01
Start Time: 2008-317T00:00 Stop Time: 2008-318T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008318_01
Start Time: 2008-318T00:00 Stop Time: 2008-319T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008319_01
Start Time: 2008-319T00:00 Stop Time: 2008-320T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008320_01
Start Time: 2008-320T00:00 Stop Time: 2008-321T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008321_01
Start Time: 2008-321T00:00 Stop Time: 2008-322T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008322_01
Start Time: 2008-322T00:00 Stop Time: 2008-323T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008323_01
Start Time: 2008-323T00:00 Stop Time: 2008-324T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008324_01
Start Time: 2008-324T00:00 Stop Time: 2008-325T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008325_01
Start Time: 2008-325T00:00 Stop Time: 2008-326T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008326_01
Start Time: 2008-326T00:00 Stop Time: 2008-327T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008327_01
Start Time: 2008-327T00:00 Stop Time: 2008-328T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008328_01
Start Time: 2008-328T00:00 Stop Time: 2008-329T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008329_01
Start Time: 2008-329T00:00 Stop Time: 2008-330T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008330_01
Start Time: 2008-330T00:00 Stop Time: 2008-331T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008331_01
Start Time: 2008-331T00:00 Stop Time: 2008-332T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008332_01
Start Time: 2008-332T00:00 Stop Time: 2008-333T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008333_01
Start Time: 2008-333T00:00 Stop Time: 2008-334T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008334_01
Start Time: 2008-334T00:00 Stop Time: 2008-335T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008335_01
Start Time: 2008-335T00:00 Stop Time: 2008-336T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008336_01
Start Time: 2008-336T00:00 Stop Time: 2008-337T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008337_01
Start Time: 2008-337T00:00 Stop Time: 2008-338T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008338_01
Start Time: 2008-338T00:00 Stop Time: 2008-339T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008339_01
Start Time: 2008-339T00:00 Stop Time: 2008-340T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008340_01
Start Time: 2008-340T00:00 Stop Time: 2008-341T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008341_01
Start Time: 2008-341T00:00 Stop Time: 2008-342T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008342_01
Start Time: 2008-342T00:00 Stop Time: 2008-343T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008343_01
Start Time: 2008-343T00:00 Stop Time: 2008-344T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008344_01
Start Time: 2008-344T00:00 Stop Time: 2008-345T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008345_01
Start Time: 2008-345T00:00 Stop Time: 2008-346T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008346_01
Start Time: 2008-346T00:00 Stop Time: 2008-347T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008347_01
Start Time: 2008-347T00:00 Stop Time: 2008-348T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008348_01
Start Time: 2008-348T00:00 Stop Time: 2008-349T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008349_01
Start Time: 2008-349T00:00 Stop Time: 2008-350T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008350_01
Start Time: 2008-350T00:00 Stop Time: 2008-351T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008351_01
Start Time: 2008-351T00:00 Stop Time: 2008-352T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008352_01
Start Time: 2008-352T00:00 Stop Time: 2008-353T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008353_01
Start Time: 2008-353T00:00 Stop Time: 2008-354T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008354_01
Start Time: 2008-354T00:00 Stop Time: 2008-355T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008355_01
Start Time: 2008-355T00:00 Stop Time: 2008-356T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008356_01
Start Time: 2008-356T00:00 Stop Time: 2008-357T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008357_01
Start Time: 2008-357T00:00 Stop Time: 2008-358T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008358_01
Start Time: 2008-358T00:00 Stop Time: 2008-359T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008359_01
Start Time: 2008-359T00:00 Stop Time: 2008-360T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008360_01
Start Time: 2008-360T00:00 Stop Time: 2008-361T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008361_01
Start Time: 2008-361T00:00 Stop Time: 2008-362T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008362_01
Start Time: 2008-362T00:00 Stop Time: 2008-363T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008363_01
Start Time: 2008-363T00:00 Stop Time: 2008-364T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008364_01
Start Time: 2008-364T00:00 Stop Time: 2008-365T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008365_01
Start Time: 2008-365T00:00 Stop Time: 2008-366T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
LPHAAVG0_1MIN_2008366_01
Start Time: 2008-366T00:00 Stop Time: 2009-001T00:00
The data columns contain 1 minute averages of
LEMMS PHA data. The data are averaged by first defining fixed one minute
intervals throughout the day and then averaging any data points that fall
in the intervals. If an interval contains no data, it is still listed in
the file, but all data intensity values will be fill. The fill value for
data in this file is -1.0E38.

These data are background subtracted, and thus occasionally there will be
negative values when the count rate falls below the background level.
Also, the uncertainties are based on the counting statistics, and thus
because of the background subtraction, the uncertainties can be larger
than the data value.

The background levels change over time and each channel's background level
as a function of time in counts/sec is listed in the MIMI calibration file
(described in the MIMI Data User Guide, the SIS for this dataset, and also
in SIS for the uncalibrated MIMI data).

There are three types of channels included in these averages: the A
channels, the E channels and the F1 channels. The A channels measure ions,
mostly protons. The E and F1 channels measure electrons. The MIMI
instrument paper describes these channels, as does the MIMI Data User
Guide. For the A channels, channel indices 8 through 62 are present
(energies of 26-758 keV). For the E channels, indices 15 to 62 (20-410
keV), and for F1, 26 through 59 (206-1717 keV).

Note that a subset of the available PHA channels are typically used for
science analysis, and only these channels are plotted here. The dataset
catalog file details the reasons for this. Essentially, the efficiencies
are unknown or uncertain for omitted channels.

The file header and leading columns of the file are present to make the
format consistent with other MIMI data in the PDS. Note that much of the
values for the leading columns are -1, indicating that they do not have
useful values, but their presence allows this file to be parsed by the
same code that reads other MIMI PDS data. The first column is always the
string 'sci', the next column is a UTC string, and then these prefix
columns have no data in them but are just there to preserve the format:
UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector
Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
Staring  Sensor_Bitrate

Just before the data columns are three columns giving the position of the
Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
given for the middle of the time interval. The units are Saturn radii
(60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
+Z cross the Saturn-Sun line, and +X is +Y cross +Z.
ICON LEGEND
For links to data holdings various icons are used to represent services or actions you can take. Those icons are:
Order the volume (CD-ROM/DVD) containing the listed data. The volume will be mailed to you. The volume (CD-ROM/DVD) contains some errors which are documented in an errata log.
Launch a custom web browser for the resource. Launch a map based browser for the resource.
Toggle viewing into brief mode (shorter descriptions are displayed). Toggle viewing into expanded mode (longer descriptions are displayed).
Download the volume containing the listed data.


NEW RELEASES

More.....

PDS RESOURCES

Archive Planning Guide
      Individuals
      Missions
Data Dictionary Search
      Lookup Tool
      Document
PDS4 Standards Documents
PDS Subscription Service

PDS3 Standards

OTHER RESOURCES

ADS Search
Science Data Licenses

Privacy / Copyright
Freedom of Information Act
Web Master: PDS-PPI Operator
NASA Official: Becky McCauley-Rench