Download this file

                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "START TIME"                                  
    FIELD_NUMBER              = 1                                             
    UNIT                      = 'N/A'                                         
    DATA_TYPE                 = CHARACTER                                     
    BYTES                     = 24                                            
    FORMAT                    = A24                                           
    VALID_MINIMUM             = "N/A"                                         
    VALID_MAXIMUM             = "N/A"                                         
    DESCRIPTION               = "                                             
      Spacecraft event time (UT) at which the particle counting begins.       
      Time is given in the format of `yyyy-ddd hh:mm:ss.sss '."               
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "STOP TIME"                                   
    FIELD_NUMBER              = 2                                             
    UNIT                      = 'N/A'                                         
    DATA_TYPE                 = CHARACTER                                     
    BYTES                     = 24                                            
    FORMAT                    = A24                                           
    VALID_MINIMUM             = "N/A"                                         
    VALID_MAXIMUM             = "N/A"                                         
    DESCRIPTION               = "                                             
      Spacecraft event time (UT) at which the particle counting ends.         
      Time is given in the format of `yyyy-ddd hh:mm:ss.sss '."               
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "SECTOR"                                      
    FIELD_NUMBER              = 2                                             
    UNIT                      = 'N/A'                                         
    DATA_TYPE                 = ASCII_INTEGER                                 
    BYTES                     = 1                                             
    FORMAT                    = I1                                            
    VALID_MINIMUM             = 1                                             
    VALID_MAXIMUM             = 8                                             
    DESCRIPTION               = "                                             
      LECP stepping platform position (1-8). Unknown if 9."                   
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "SCAN_DIR"                                    
    FIELD_NUMBER              = 4                                             
    UNIT                      = 'N/A'                                         
    DATA_TYPE                 = ASCII_INTEGER                                 
    BYTES                     = 1                                             
    FORMAT                    = I2                                            
    VALID_MINIMUM             = -1                                            
    VALID_MAXIMUM             =  1                                            
    DESCRIPTION               = "                                             
      LECP scan direction of the sector                                       
      (1 = for increasing; -1 = for decreasing."                              
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "PL01_FLUX"                                   
    FIELD_NUMBER              = 5                                             
    UNIT                      = "CM**-2 SEC**-1 SR**-1"                       
    DATA_TYPE                 = ASCII_REAL                                    
    BYTES                     = 13                                            
    FORMAT                    = "F13.1"                                       
    VALID_MINIMUM             = 0.0                                           
    VALID_MAXIMUM             = 99999999999.9                                 
    DESCRIPTION               = "                                             
      Flux measured in energy channel PL01                                    
      (24-48 keV/nuc. protons and ions)."                                     
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "PL01_FLUX_UNCERTAINTY"                       
    FIELD_NUMBER              = 6                                             
    UNIT                      = "CM**-2 SEC**-1 SR**-1"                       
    DATA_TYPE                 = ASCII_REAL                                    
    BYTES                     = 9                                             
    FORMAT                    = "F9.1"                                        
    VALID_MINIMUM             = 0.0                                           
    VALID_MAXIMUM             = 9999999.9                                     
    DESCRIPTION               = "                                             
      Flux uncertainty for channel PL01."                                     
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "PL02_FLUX"                                   
    FIELD_NUMBER              = 7                                             
    UNIT                      = "CM**-2 SEC**-1 SR**-1"                       
    DATA_TYPE                 = ASCII_REAL                                    
    BYTES                     = 13                                            
    FORMAT                    = "F13.1"                                       
    VALID_MINIMUM             = 0.0                                           
    VALID_MAXIMUM             = 99999999999.9                                 
    DESCRIPTION               = "                                             
      Flux measured in energy channel PL02                                    
      (48-80 keV/nuc. protons and ions)."                                     
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "PL02_FLUX_UNCERTAINTY"                       
    FIELD_NUMBER              = 8                                             
    UNIT                      = "CM**-2 SEC**-1 SR**-1"                       
    DATA_TYPE                 = ASCII_REAL                                    
    BYTES                     = 9                                             
    FORMAT                    = "F9.1"                                        
    VALID_MINIMUM             = 0.0                                           
    VALID_MAXIMUM             = 9999999.9                                     
    DESCRIPTION               = "                                             
      Flux uncertainty for channel PL02."                                     
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "PL03_FLUX"                                   
    FIELD_NUMBER              = 9                                             
    UNIT                      = "CM**-2 SEC**-1 SR**-1"                       
    DATA_TYPE                 = ASCII_REAL                                    
    BYTES                     = 13                                            
    FORMAT                    = "F13.1"                                       
    VALID_MINIMUM             = 0.0                                           
    VALID_MAXIMUM             = 99999999999.9                                 
    DESCRIPTION               = "                                             
      Flux measured in energy channel PL03                                    
      (80-137 keV/nuc. protons and ions)."                                    
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "PL03_FLUX_UNCERTAINTY"                       
    FIELD_NUMBER              = 10                                            
    UNIT                      = "CM**-2 SEC**-1 SR**-1"                       
    DATA_TYPE                 = ASCII_REAL                                    
    BYTES                     = 9                                             
    FORMAT                    = "F9.1"                                        
    VALID_MINIMUM             = 0.0                                           
    VALID_MAXIMUM             = 9999999.9                                     
    DESCRIPTION               = "                                             
      Flux uncertainty for channel PL03."                                     
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "PL04_FLUX"                                   
    FIELD_NUMBER              = 11                                            
    UNIT                      = "CM**-2 SEC**-1 SR**-1"                       
    DATA_TYPE                 = ASCII_REAL                                    
    BYTES                     = 13                                            
    FORMAT                    = "F13.1"                                       
    VALID_MINIMUM             = 0.0                                           
    VALID_MAXIMUM             = 99999999999.9                                 
    DESCRIPTION               = "                                             
      Flux measured in energy channel PL04                                    
      (137-215 keV/nuc. protons and ions)."                                   
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "PL04_FLUX_UNCERTAINTY"                       
    FIELD_NUMBER              = 12                                            
    UNIT                      = "CM**-2 SEC**-1 SR**-1"                       
    DATA_TYPE                 = ASCII_REAL                                    
    BYTES                     = 9                                             
    FORMAT                    = "F9.1"                                        
    VALID_MINIMUM             = 0.0                                           
    VALID_MAXIMUM             = 9999999.9                                     
    DESCRIPTION               = "                                             
      Flux uncertainty for channel PL04."                                     
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "PL05_FLUX"                                   
    FIELD_NUMBER              = 13                                            
    UNIT                      = "CM**-2 SEC**-1 SR**-1"                       
    DATA_TYPE                 = ASCII_REAL                                    
    BYTES                     = 13                                            
    FORMAT                    = "F13.1"                                       
    VALID_MINIMUM             = 0.0                                           
    VALID_MAXIMUM             = 99999999999.9                                 
    DESCRIPTION               = "                                             
      Flux measured in energy channel PL05                                    
      (215-540 keV/nuc. protons and ions)."                                   
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "PL05_FLUX_UNCERTAINTY"                       
    FIELD_NUMBER              = 14                                            
    UNIT                      = "CM**-2 SEC**-1 SR**-1"                       
    DATA_TYPE                 = ASCII_REAL                                    
    BYTES                     = 9                                             
    FORMAT                    = "F9.1"                                        
    VALID_MINIMUM             = 0.0                                           
    VALID_MAXIMUM             = 9999999.9                                     
    DESCRIPTION               = "                                             
      Flux uncertainty for channel PL05."                                     
  END_OBJECT                  = FIELD