  OBJECT                      = FIELD                                         
    NAME                      = "START TIME"                                  
    FIELD_NUMBER              = 1                                             
    UNIT                      = 'N/A'                                         
    DATA_TYPE                 = CHARACTER                                     
    BYTES                     = 24                                            
    FORMAT                    = A24                                           
    VALID_MINIMUM             = "N/A"                                         
    VALID_MAXIMUM             = "N/A"                                         
    DESCRIPTION               = "                                             
      Spacecraft event time (UT) at which the particle counting begins.       
      Time is given in the format of `yyyy-ddd hh:mm:ss.sss '."               
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "STOP TIME"                                   
    FIELD_NUMBER              = 2                                             
    UNIT                      = 'N/A'                                         
    DATA_TYPE                 = CHARACTER                                     
    BYTES                     = 24                                            
    FORMAT                    = A24                                           
    VALID_MINIMUM             = "N/A"                                         
    VALID_MAXIMUM             = "N/A"                                         
    DESCRIPTION               = "                                             
      Spacecraft event time (UT) at which the particle counting ends.         
      Time is given in the format of `yyyy-ddd hh:mm:ss.sss '."               
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "SECTOR"                                      
    FIELD_NUMBER              = 2                                             
    UNIT                      = 'N/A'                                         
    DATA_TYPE                 = ASCII_INTEGER                                 
    BYTES                     = 1                                             
    FORMAT                    = I1                                            
    VALID_MINIMUM             = 1                                             
    VALID_MAXIMUM             = 8                                             
    DESCRIPTION               = "                                             
      LECP stepping platform position (1-8). Unknown if 9."                   
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "SCAN_DIR"                                    
    FIELD_NUMBER              = 4                                             
    UNIT                      = 'N/A'                                         
    DATA_TYPE                 = ASCII_INTEGER                                 
    BYTES                     = 1                                             
    FORMAT                    = I2                                            
    VALID_MINIMUM             = -1                                            
    VALID_MAXIMUM             =  1                                            
    DESCRIPTION               = "                                             
      LECP scan direction of the sector                                       
      (1 = for increasing; -1 = for decreasing."                              
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "A12_RATE"                                    
    FIELD_NUMBER              = 5                                             
    UNIT                      = "COUNTS"                                      
    DATA_TYPE                 = ASCII_REAL                                    
    BYTES                     = 13                                            
    FORMAT                    = "F13.1"                                       
    VALID_MINIMUM             = 0.0                                           
    VALID_MAXIMUM             = 99999999999.9                                 
    DESCRIPTION               = "                                             
      Counting rate measured in energy channel A12                            
      (4.2-7.8 MeV/nuc. alpha particles)."                                    
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "A12_RATE_UNCERTAINTY"                        
    FIELD_NUMBER              = 6                                             
    UNIT                      = "COUNTS"                                      
    DATA_TYPE                 = ASCII_REAL                                    
    BYTES                     = 9                                             
    FORMAT                    = "F9.1"                                        
    VALID_MINIMUM             = 0.0                                           
    VALID_MAXIMUM             = 9999999.9                                     
    DESCRIPTION               = "                                             
      Rate uncertainty for channel A12."                                      
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "A13_RATE"                                    
    FIELD_NUMBER              = 7                                             
    UNIT                      = "COUNTS"                                      
    DATA_TYPE                 = ASCII_REAL                                    
    BYTES                     = 13                                            
    FORMAT                    = "F13.1"                                       
    VALID_MINIMUM             = 0.0                                           
    VALID_MAXIMUM             = 99999999999.9                                 
    DESCRIPTION               = "                                             
      Counting rate measured in energy channel A13                            
      (7.8-20.0 MeV/nuc. alpha particles)."                                   
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "A13_RATE_UNCERTAINTY"                        
    FIELD_NUMBER              = 8                                             
    UNIT                      = "COUNTS"                                      
    DATA_TYPE                 = ASCII_REAL                                    
    BYTES                     = 9                                             
    FORMAT                    = "F9.1"                                        
    VALID_MINIMUM             = 0.0                                           
    VALID_MAXIMUM             = 9999999.9                                     
    DESCRIPTION               = "                                             
      Rate uncertainty for channel A13."                                      
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "L14_RATE"                                    
    FIELD_NUMBER              = 9                                             
    UNIT                      = "COUNTS"                                      
    DATA_TYPE                 = ASCII_REAL                                    
    BYTES                     = 13                                            
    FORMAT                    = "F13.1"                                       
    VALID_MINIMUM             = 0.0                                           
    VALID_MAXIMUM             = 99999999999.9                                 
    DESCRIPTION               = "                                             
      Counting rate measured in energy channel L14                            
      (5.8-28.0 MeV/nuc. light nuclei, 3 ❮= Z ❮ 6)."                          
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "L14_RATE_UNCERTAINTY"                        
    FIELD_NUMBER              = 10                                            
    UNIT                      = "COUNTS"                                      
    DATA_TYPE                 = ASCII_REAL                                    
    BYTES                     = 9                                             
    FORMAT                    = "F9.1"                                        
    VALID_MINIMUM             = 0.0                                           
    VALID_MAXIMUM             = 9999999.9                                     
    DESCRIPTION               = "                                             
      Rate uncertainty for channel L14."                                      
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "M15_RATE"                                    
    FIELD_NUMBER              = 11                                            
    UNIT                      = "COUNTS"                                      
    DATA_TYPE                 = ASCII_REAL                                    
    BYTES                     = 13                                            
    FORMAT                    = "F13.1"                                       
    VALID_MINIMUM             = 0.0                                           
    VALID_MAXIMUM             = 99999999999.9                                 
    DESCRIPTION               = "                                             
      Counting rate measured in energy channel M15                            
      (8.6-40.0 MeV/nuc. medium nuclei, 6 ❮= Z ❮ 8)."                         
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "M15_RATE_UNCERTAINTY"                        
    FIELD_NUMBER              = 12                                            
    UNIT                      = "COUNTS"                                      
    DATA_TYPE                 = ASCII_REAL                                    
    BYTES                     = 9                                             
    FORMAT                    = "F9.1"                                        
    VALID_MINIMUM             = 0.0                                           
    VALID_MAXIMUM             = 9999999.9                                     
    DESCRIPTION               = "                                             
      Rate uncertainty for channel M15."                                      
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "H43_RATE"                                    
    FIELD_NUMBER              = 13                                            
    UNIT                      = "COUNTS"                                      
    DATA_TYPE                 = ASCII_REAL                                    
    BYTES                     = 13                                            
    FORMAT                    = "F13.1"                                       
    VALID_MINIMUM             = 0.0                                           
    VALID_MAXIMUM             = 99999999999.9                                 
    DESCRIPTION               = "                                             
      Counting rate measured in energy channel H43                            
      (11.8-74.0 MeV/nuc. heavy nuclei, Z ❯= 8)."                             
  END_OBJECT                  = FIELD                                         
                                                                              
  OBJECT                      = FIELD                                         
    NAME                      = "H43_RATE_UNCERTAINTY"                        
    FIELD_NUMBER              = 14                                            
    UNIT                      = "COUNTS"                                      
    DATA_TYPE                 = ASCII_REAL                                    
    BYTES                     = 9                                             
    FORMAT                    = "F9.1"                                        
    VALID_MINIMUM             = 0.0                                           
    VALID_MAXIMUM             = 9999999.9                                     
    DESCRIPTION               = "                                             
      Rate uncertainty for channel H43."                                      
  END_OBJECT                  = FIELD