/* PDS FORMAT FILE FOR RAD ANALOG ELECTRONIC (RAE) HOUSEKEEPING DATA*/
OBJECT = COLUMN
NAME = VIRENA_OUTPUT
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 1
BYTES = 2
DESCRIPTION = "ADC (Analog to Digital Converter) reading of
VIRENA output."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = ANALOG_GROUND_1
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 3
BYTES = 2
DESCRIPTION = "First analog ground ADC (Analog to Digital
Converter) reading."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = ANALOG_GROUND_2
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 5
BYTES = 2
DESCRIPTION = "Second analog ground ADC (Analog to Digital
Converter) reading."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = ADC_CALIBRATION_HIGH
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 7
BYTES = 2
DESCRIPTION = "Voltage that is 1/2 percent from maximum high for ADC"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = ADC_CALIBRATION_LOW
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 9
BYTES = 2
DESCRIPTION = "Voltage that is 1/2 percent higher than ADC minimum."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = VOLTAGE_CAL_LOW
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 11
BYTES = 2
DESCRIPTION = "Voltage that is 15 mV higher than VOLTAGE_REF_LOW."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = VOLTAGE_REF_LOW
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 13
BYTES = 2
DESCRIPTION = "Supply voltages that go to the VIRENA, should be 1.5
units??"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = DAC_REFENENCE
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 15
BYTES = 2
DESCRIPTION = "DAC (Digital to Analog Converter) reference to VIRENA
~3.0V (flight) 1.0V (eng)."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = BIAS_70
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 17
BYTES = 2
DESCRIPTION = "Measured bias current for 70 volt supply. "
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = POSITIVE_5V_SENSOR
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 19
BYTES = 2
DESCRIPTION = "Positivie 5V sensor for RSH."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = NEGATIVE_5V_ANALOG
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 21
BYTES = 2
DESCRIPTION = "Negative 5V for analog."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = POSITIVE_5V_ANALOG
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 23
BYTES = 2
DESCRIPTION = "Postive 5V for analog."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = TEMPERATURE_4
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 25
BYTES = 2
DESCRIPTION = "Temperature for temp_4 thermistor for CDH"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = TEMPERATURE_3
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 27
BYTES = 2
DESCRIPTION = "Temperature for temp_3 thermistor.
RSH internal temperature - near detector D"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = TEMPERATURE_2
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 29
BYTES = 2
DESCRIPTION = "Temperature for temp_2 thermistor.
RSH internal temperature - near detector D (opposite
side of temp_3)"
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = TEMPERATURE_1
DATA_TYPE = MSB_UNSIGNED_INTEGER
START_BYTE = 31
BYTES = 2
DESCRIPTION = "Temperature for temp_3 thermistor.
RSH internal temperature - near detector A"
END_OBJECT = COLUMN
|