OBJECT = COLUMN
NAME = SECONDS
COLUMN_NUMBER = 1
START_BYTE = 1
BYTES = 9
DATA_TYPE = ASCII_INTEGER
FORMAT = I9
UNIT = SECONDS
DESCRIPTION = "Spacecraft Time (elapsed seconds from epoch
2001-01-01T00:00:00.000 UTC)."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = FRACT
COLUMN_NUMBER = 2
START_BYTE = 11
BYTES = 2
DATA_TYPE = ASCII_INTEGER
FORMAT = I2
UNIT = "1/100 SECOND"
DESCRIPTION = "Spacecraft Time--Fractional Second."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = V5DIGITAL
COLUMN_NUMBER = 3
START_BYTE = 14
BYTES = 7
DATA_TYPE = ASCII_INTEGER
FORMAT = I7
UNIT = VOLTS
DESCRIPTION = "+5VDC Digital Regulated Voltage."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = VANALOGERR
COLUMN_NUMBER = 4
START_BYTE = 22
BYTES = 2
DATA_TYPE = ASCII_INTEGER
FORMAT = I2
UNIT = "N/A"
DESCRIPTION = "Analog Voltage Status Indicator (0 = on; 15 = off,
remaining H/K invalid)."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = V5PLUS
COLUMN_NUMBER = 5
START_BYTE = 25
BYTES = 7
DATA_TYPE = ASCII_REAL
FORMAT = "F7.3"
UNIT = VOLTS
DESCRIPTION = "+5VDC Analog Regulated Voltage."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = V5NEG
COLUMN_NUMBER = 6
START_BYTE = 33
BYTES = 7
DATA_TYPE = ASCII_REAL
FORMAT = "F7.3"
UNIT = VOLTS
DESCRIPTION = "-5VDC Analog Regulated Voltage."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = BIASCURRENT
COLUMN_NUMBER = 7
START_BYTE = 41
BYTES = 47
ITEM_BYTES = 7
ITEM_OFFSET = 8
ITEMS = 6
DATA_TYPE = ASCII_REAL
FORMAT = "F7.3"
UNIT = MICROAMPS
DESCRIPTION = "Detector Bias Currents."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = BIASVOLTTHIN
COLUMN_NUMBER = 8
START_BYTE = 89
BYTES = 7
DATA_TYPE = ASCII_REAL
FORMAT = "F7.3"
UNIT = VOLTS
DESCRIPTION = "Thin Detector (D1, D3, D5) Bias Voltage."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = BIASVOLTTHICK
COLUMN_NUMBER = 9
START_BYTE = 97
BYTES = 7
DATA_TYPE = ASCII_REAL
FORMAT = "F7.3"
UNIT = VOLTS
DESCRIPTION = "Thick Detector (D2, D4, D6) Bias Voltage."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = CALAMP
COLUMN_NUMBER = 10
START_BYTE = 105
BYTES = 7
DATA_TYPE = ASCII_REAL
FORMAT = "F7.3"
UNIT = VOLTS
DESCRIPTION = "Internal Calibration Pulser Pulse Amplitude."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = LLDTHIN
COLUMN_NUMBER = 11
START_BYTE = 113
BYTES = 7
DATA_TYPE = ASCII_REAL
FORMAT = "F7.3"
UNIT = VOLTS
DESCRIPTION = "LLD Signal Threshold--Thin Detectors (D1, D3, D5)."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = LLDTHICK
COLUMN_NUMBER = 12
START_BYTE = 121
BYTES = 7
DATA_TYPE = ASCII_REAL
FORMAT = "F7.3"
UNIT = VOLTS
DESCRIPTION = "LLD Signal Threshold--Thick Detectors (D2, D4, D6)."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = TTELESCOPE
COLUMN_NUMBER = 13
START_BYTE = 129
BYTES = 7
DATA_TYPE = ASCII_REAL
FORMAT = "F7.2"
UNIT = CELSIUS
DESCRIPTION = "Temperature--Telescope Assembly."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = TANALOG
COLUMN_NUMBER = 14
START_BYTE = 137
BYTES = 7
DATA_TYPE = ASCII_REAL
FORMAT = "F7.2"
UNIT = CELSIUS
DESCRIPTION = "Temperature--Analog Electronics Board."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = TDIGITAL
COLUMN_NUMBER = 15
START_BYTE = 145
BYTES = 7
DATA_TYPE = ASCII_REAL
FORMAT = "F7.2"
UNIT = CELSIUS
DESCRIPTION = "Temperature--Digital Electronics Board."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = TPOWER
COLUMN_NUMBER = 16
START_BYTE = 153
BYTES = 7
DATA_TYPE = ASCII_REAL
FORMAT = "F7.2"
UNIT = CELSIUS
DESCRIPTION = "Temperature--Power Supply."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = TREF
COLUMN_NUMBER = 17
START_BYTE = 161
BYTES = 7
DATA_TYPE = ASCII_REAL
FORMAT = "F7.2"
UNIT = CELSIUS
DESCRIPTION = "Temperature--Reference Location, Telescope Housing
Wall."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = RADHIGHSENS
COLUMN_NUMBER = 18
START_BYTE = 169
BYTES = 10
DATA_TYPE = ASCII_REAL
FORMAT = "E10.4"
UNIT = RADS
DESCRIPTION = "Radiation Monitor Integrated Dose--High Sensitivity."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = RADMEDSENS
COLUMN_NUMBER = 19
START_BYTE = 180
BYTES = 10
DATA_TYPE = ASCII_REAL
FORMAT = "E10.4"
UNIT = RADS
DESCRIPTION = "Radiation Monitor Integrated Dose--Medium
Sensitivity."
END_OBJECT = COLUMN
OBJECT = COLUMN
NAME = RADLOWSENS
COLUMN_NUMBER = 20
START_BYTE = 191
BYTES = 10
DATA_TYPE = ASCII_REAL
FORMAT = "E10.4"
UNIT = RADS
DESCRIPTION = "Radiation Monitor Integrated Dose--Low Sensitivity."
END_OBJECT = COLUMN
|