Download this file |
OBJECT = COLUMN NAME = SECONDS COLUMN_NUMBER = 1 START_BYTE = 1 BYTES = 9 DATA_TYPE = ASCII_INTEGER FORMAT = I9 UNIT = SECONDS DESCRIPTION = "Spacecraft Time (elapsed seconds from epoch 2001-01-01T00:00:00.000 UTC)." END_OBJECT = COLUMN OBJECT = COLUMN NAME = FRACT COLUMN_NUMBER = 2 START_BYTE = 11 BYTES = 2 DATA_TYPE = ASCII_INTEGER FORMAT = I2 UNIT = "1/100 SECOND" DESCRIPTION = "Spacecraft Time--Fractional Second." END_OBJECT = COLUMN OBJECT = COLUMN NAME = V5DIGITAL COLUMN_NUMBER = 3 START_BYTE = 14 BYTES = 7 DATA_TYPE = ASCII_INTEGER FORMAT = I7 UNIT = VOLTS DESCRIPTION = "+5VDC Digital Regulated Voltage." END_OBJECT = COLUMN OBJECT = COLUMN NAME = VANALOGERR COLUMN_NUMBER = 4 START_BYTE = 22 BYTES = 2 DATA_TYPE = ASCII_INTEGER FORMAT = I2 UNIT = "N/A" DESCRIPTION = "Analog Voltage Status Indicator (0 = on; 15 = off, remaining H/K invalid)." END_OBJECT = COLUMN OBJECT = COLUMN NAME = V5PLUS COLUMN_NUMBER = 5 START_BYTE = 25 BYTES = 7 DATA_TYPE = ASCII_REAL FORMAT = "F7.3" UNIT = VOLTS DESCRIPTION = "+5VDC Analog Regulated Voltage." END_OBJECT = COLUMN OBJECT = COLUMN NAME = V5NEG COLUMN_NUMBER = 6 START_BYTE = 33 BYTES = 7 DATA_TYPE = ASCII_REAL FORMAT = "F7.3" UNIT = VOLTS DESCRIPTION = "-5VDC Analog Regulated Voltage." END_OBJECT = COLUMN OBJECT = COLUMN NAME = BIASCURRENT COLUMN_NUMBER = 7 START_BYTE = 41 BYTES = 47 ITEM_BYTES = 7 ITEM_OFFSET = 8 ITEMS = 6 DATA_TYPE = ASCII_REAL FORMAT = "F7.3" UNIT = MICROAMPS DESCRIPTION = "Detector Bias Currents." END_OBJECT = COLUMN OBJECT = COLUMN NAME = BIASVOLTTHIN COLUMN_NUMBER = 8 START_BYTE = 89 BYTES = 7 DATA_TYPE = ASCII_REAL FORMAT = "F7.3" UNIT = VOLTS DESCRIPTION = "Thin Detector (D1, D3, D5) Bias Voltage." END_OBJECT = COLUMN OBJECT = COLUMN NAME = BIASVOLTTHICK COLUMN_NUMBER = 9 START_BYTE = 97 BYTES = 7 DATA_TYPE = ASCII_REAL FORMAT = "F7.3" UNIT = VOLTS DESCRIPTION = "Thick Detector (D2, D4, D6) Bias Voltage." END_OBJECT = COLUMN OBJECT = COLUMN NAME = CALAMP COLUMN_NUMBER = 10 START_BYTE = 105 BYTES = 7 DATA_TYPE = ASCII_REAL FORMAT = "F7.3" UNIT = VOLTS DESCRIPTION = "Internal Calibration Pulser Pulse Amplitude." END_OBJECT = COLUMN OBJECT = COLUMN NAME = LLDTHIN COLUMN_NUMBER = 11 START_BYTE = 113 BYTES = 7 DATA_TYPE = ASCII_REAL FORMAT = "F7.3" UNIT = VOLTS DESCRIPTION = "LLD Signal Threshold--Thin Detectors (D1, D3, D5)." END_OBJECT = COLUMN OBJECT = COLUMN NAME = LLDTHICK COLUMN_NUMBER = 12 START_BYTE = 121 BYTES = 7 DATA_TYPE = ASCII_REAL FORMAT = "F7.3" UNIT = VOLTS DESCRIPTION = "LLD Signal Threshold--Thick Detectors (D2, D4, D6)." END_OBJECT = COLUMN OBJECT = COLUMN NAME = TTELESCOPE COLUMN_NUMBER = 13 START_BYTE = 129 BYTES = 7 DATA_TYPE = ASCII_REAL FORMAT = "F7.2" UNIT = CELSIUS DESCRIPTION = "Temperature--Telescope Assembly." END_OBJECT = COLUMN OBJECT = COLUMN NAME = TANALOG COLUMN_NUMBER = 14 START_BYTE = 137 BYTES = 7 DATA_TYPE = ASCII_REAL FORMAT = "F7.2" UNIT = CELSIUS DESCRIPTION = "Temperature--Analog Electronics Board." END_OBJECT = COLUMN OBJECT = COLUMN NAME = TDIGITAL COLUMN_NUMBER = 15 START_BYTE = 145 BYTES = 7 DATA_TYPE = ASCII_REAL FORMAT = "F7.2" UNIT = CELSIUS DESCRIPTION = "Temperature--Digital Electronics Board." END_OBJECT = COLUMN OBJECT = COLUMN NAME = TPOWER COLUMN_NUMBER = 16 START_BYTE = 153 BYTES = 7 DATA_TYPE = ASCII_REAL FORMAT = "F7.2" UNIT = CELSIUS DESCRIPTION = "Temperature--Power Supply." END_OBJECT = COLUMN OBJECT = COLUMN NAME = TREF COLUMN_NUMBER = 17 START_BYTE = 161 BYTES = 7 DATA_TYPE = ASCII_REAL FORMAT = "F7.2" UNIT = CELSIUS DESCRIPTION = "Temperature--Reference Location, Telescope Housing Wall." END_OBJECT = COLUMN OBJECT = COLUMN NAME = RADHIGHSENS COLUMN_NUMBER = 18 START_BYTE = 169 BYTES = 10 DATA_TYPE = ASCII_REAL FORMAT = "E10.4" UNIT = RADS DESCRIPTION = "Radiation Monitor Integrated Dose--High Sensitivity." END_OBJECT = COLUMN OBJECT = COLUMN NAME = RADMEDSENS COLUMN_NUMBER = 19 START_BYTE = 180 BYTES = 10 DATA_TYPE = ASCII_REAL FORMAT = "E10.4" UNIT = RADS DESCRIPTION = "Radiation Monitor Integrated Dose--Medium Sensitivity." END_OBJECT = COLUMN OBJECT = COLUMN NAME = RADLOWSENS COLUMN_NUMBER = 20 START_BYTE = 191 BYTES = 10 DATA_TYPE = ASCII_REAL FORMAT = "E10.4" UNIT = RADS DESCRIPTION = "Radiation Monitor Integrated Dose--Low Sensitivity." END_OBJECT = COLUMN |