Download this file

OBJECT               = COLUMN
  NAME               = HEADER
  COLUMN_NUMBER      = 1
  START_BYTE         = 1
  BYTES              = 12
  ^STRUCTURE         = "CRAT_L0_HDR.FMT"
  DATA_TYPE          = BIT_STRING
  DESCRIPTION        = "CCSDS Primary and Secondary Headers, ApId = 122."
END_OBJECT           = COLUMN
OBJECT               = COLUMN
  NAME               = CRATVERFPGA
  COLUMN_NUMBER      = 2
  START_BYTE         = 13
  BYTES              = 2
  DATA_TYPE          = BIT_STRING
  DESCRIPTION        = "FPGA Revision Code."
  OBJECT             = BIT_COLUMN
    NAME             = FPGA_SN
    COLUMN_NUMBER    = 1
    START_BIT        = 1
    BITS             = 4
    BIT_DATA_TYPE    = MSB_UNSIGNED_INTEGER
    MINIMUM          = 0
    MAXIMUM          = 15
    DESCRIPTION      = "FPGA Revision Code."
  END_OBJECT         = BIT_COLUMN
  OBJECT             = BIT_COLUMN
    NAME             = "N/A"
    COLUMN_NUMBER    = 2
    START_BIT        = 5
    BITS             = 12
    BIT_DATA_TYPE    = "N/A"
    DESCRIPTION      = "Unused."
  END_OBJECT         = BIT_COLUMN
END_OBJECT           = COLUMN
OBJECT               = COLUMN
  NAME               = V5DIGITAL
  COLUMN_NUMBER      = 3
  START_BYTE         = 15
  BYTES              = 2
  DATA_TYPE          = MSB_UNSIGNED_INTEGER
  UNIT               = "N/A"
  MINIMUM            = 0
  MAXIMUM            = 4095
  DESCRIPTION        = "+5VDC Digital Regulated Voltage Monitor Value."
  NOTE               = "VOLTS = 0.00200*DN"
END_OBJECT           = COLUMN
OBJECT               = COLUMN
  NAME               = CRATV5PLUS
  COLUMN_NUMBER      = 4
  START_BYTE         = 17
  BYTES              = 2
  DATA_TYPE          = BIT_STRING
  DESCRIPTION        = "Analog Voltage Status Indicator and +5VDC Analog
                       Regulated Voltage Monitor Value."
  OBJECT             = BIT_COLUMN
    NAME             = VANALOGERR
    COLUMN_NUMBER    = 1
    START_BIT        = 1
    BITS             = 4
    BIT_DATA_TYPE    = MSB_UNSIGNED_INTEGER
    MINIMUM          = 0
    MAXIMUM          = 15
    DESCRIPTION      = "Analog Voltage Status Indicator (0 = on; 15 = off,
                       remaining H/K invalid)."
  END_OBJECT         = BIT_COLUMN
  OBJECT             = BIT_COLUMN
    NAME             = V5PLUS
    COLUMN_NUMBER    = 2
    START_BIT        = 5
    BITS             = 12
    BIT_DATA_TYPE    = MSB_UNSIGNED_INTEGER
    UNIT             = "N/A"
    MINIMUM          = 0
    MAXIMUM          = 4095
    DESCRIPTION      = "+5VDC Analog Regulated Voltage Monitor Value."
    NOTE             = "VOLTS = 0.00200*DN"
  END_OBJECT         = BIT_COLUMN
END_OBJECT           = COLUMN
OBJECT               = COLUMN
  NAME               = V5NEG
  COLUMN_NUMBER      = 5
  START_BYTE         = 19
  BYTES              = 2
  DATA_TYPE          = MSB_UNSIGNED_INTEGER
  UNIT               = "N/A"
  MINIMUM            = 0
  MAXIMUM            = 4095
  DESCRIPTION        = "-5VDC Analog Regulated Voltage Monitor Value."
  NOTE               = "VOLTS = -0.00201*DN"
END_OBJECT           = COLUMN
OBJECT               = COLUMN
  NAME               = "N/A"
  COLUMN_NUMBER      = 6
  START_BYTE         = 21
  BYTES              = 2
  DATA_TYPE          = "N/A"
  DESCRIPTION        = "Unused."
END_OBJECT           = COLUMN
OBJECT               = COLUMN
  NAME               = BIASCURRENT
  COLUMN_NUMBER      = 7
  START_BYTE         = 23
  BYTES              = 12
  ITEM_BYTES         = 2
  ITEMS              = 6
  DATA_TYPE          = MSB_UNSIGNED_INTEGER
  UNIT               = "N/A"
  MINIMUM            = 0
  MAXIMUM            = 4095
  DESCRIPTION        = "Detector Bias Current Monitor Values."
  NOTE               = "AMPS = 5E-10*DN, 5E-9*DN, 5E-10*DN, ..."
END_OBJECT           = COLUMN
OBJECT               = COLUMN
  NAME               = BIASVOLTTHIN
  COLUMN_NUMBER      = 8
  START_BYTE         = 35
  BYTES              = 2
  DATA_TYPE          = MSB_UNSIGNED_INTEGER
  UNIT               = "N/A"
  MINIMUM            = 0
  MAXIMUM            = 4095
  DESCRIPTION        = "Thin Detector (D1, D3, D5) Bias Monitor Value."
  NOTE               = "VOLTS = 0.101*DN"
END_OBJECT           = COLUMN
OBJECT               = COLUMN
  NAME               = BIASVOLTTHICK
  COLUMN_NUMBER      = 9
  START_BYTE         = 37
  BYTES              = 2
  DATA_TYPE          = MSB_UNSIGNED_INTEGER
  UNIT               = "N/A"
  MINIMUM            = 0
  MAXIMUM            = 4095
  DESCRIPTION        = "Thick Detector (D2, D4, D6) Bias Monitor Value."
  NOTE               = "VOLTS = 0.101*DN"
END_OBJECT           = COLUMN
OBJECT               = COLUMN
  NAME               = CALAMP
  COLUMN_NUMBER      = 10
  START_BYTE         = 39
  BYTES              = 2
  DATA_TYPE          = MSB_UNSIGNED_INTEGER
  UNIT               = "N/A"
  MINIMUM            = 0
  MAXIMUM            = 4095
  DESCRIPTION        = "Internal Calibration Pulser Amplitude Monitor Value."
  NOTE               = "VOLTS = 0.00100*DN"
END_OBJECT           = COLUMN
OBJECT               = COLUMN
  NAME               = LLDTHIN
  COLUMN_NUMBER      = 11
  START_BYTE         = 41
  BYTES              = 2
  DATA_TYPE          = MSB_UNSIGNED_INTEGER
  UNIT               = "N/A"
  MINIMUM            = 0
  MAXIMUM            = 4095
  DESCRIPTION        = "LLD Amplitude Monitor Value--Thin Detectors
                       (D1, D3, D5)."
  NOTE               = "VOLTS = 0.000124*DN - 0.124"
END_OBJECT           = COLUMN
OBJECT               = COLUMN
  NAME               = LLDTHICK
  COLUMN_NUMBER      = 12
  START_BYTE         = 43
  BYTES              = 2
  DATA_TYPE          = MSB_UNSIGNED_INTEGER
  UNIT               = "N/A"
  MINIMUM            = 0
  MAXIMUM            = 4095
  DESCRIPTION        = "LLD Amplitude Monitor Value--Thick Detectors
                       (D2, D4, D6)."
  NOTE               = "VOLTS = 0.000124*DN - 0.124"
END_OBJECT           = COLUMN
OBJECT               = COLUMN
  NAME               = TTELESCOPE
  COLUMN_NUMBER      = 13
  START_BYTE         = 45
  BYTES              = 2
  DATA_TYPE          = MSB_UNSIGNED_INTEGER
  UNIT               = "N/A"
  MINIMUM            = 0
  MAXIMUM            = 4095
  DESCRIPTION        = "Temperature Monitor Value--Telescope Assembly
                       (in UNITS formula V5plus in volts)."
  NOTE               = "CELSIUS = 100*V5plus - 0.100*DN - 273.2"
END_OBJECT           = COLUMN
OBJECT               = COLUMN
  NAME               = TANALOG
  COLUMN_NUMBER      = 14
  START_BYTE         = 47
  BYTES              = 2
  DATA_TYPE          = MSB_UNSIGNED_INTEGER
  UNIT               = "N/A"
  MINIMUM            = 0
  MAXIMUM            = 4095
  DESCRIPTION        = "Temperature Monitor Value--Analog Electronics Board
                       (in UNITS formula V5plus in volts)."
  NOTE               = "CELSIUS = 100*V5plus - 0.100*DN - 273.2"
END_OBJECT           = COLUMN
OBJECT               = COLUMN
  NAME               = TDIGITAL
  COLUMN_NUMBER      = 15
  START_BYTE         = 49
  BYTES              = 2
  DATA_TYPE          = MSB_UNSIGNED_INTEGER
  UNIT               = "N/A"
  MINIMUM            = 0
  MAXIMUM            = 4095
  DESCRIPTION        = "Temperature Monitor Value--Digital Electronics Board
                       (in UNITS formula V5plus in volts)."
  NOTE               = "CELSIUS = 100*V5plus - 0.100*DN - 273.2"
END_OBJECT           = COLUMN
OBJECT               = COLUMN
  NAME               = TPOWER
  COLUMN_NUMBER      = 16
  START_BYTE         = 51
  BYTES              = 2
  DATA_TYPE          = MSB_UNSIGNED_INTEGER
  UNIT               = "N/A"
  MINIMUM            = 0
  MAXIMUM            = 4095
  DESCRIPTION        = "Temperature Monitor Value--Power Supply (in UNITS
                       formula V5plus in volts)."
  NOTE               = "CELSIUS = 100*V5plus - 0.100*DN - 273.2"
END_OBJECT           = COLUMN
OBJECT               = COLUMN
  NAME               = TREF
  COLUMN_NUMBER      = 17
  START_BYTE         = 53
  BYTES              = 2
  DATA_TYPE          = MSB_UNSIGNED_INTEGER
  UNIT               = "N/A"
  MINIMUM            = 0
  MAXIMUM            = 4095
  DESCRIPTION        = "Temperature Monitor Value--Reference Location,
                       Telescope Housing Wall (in UNITS formula V5plus in
                       volts)."
  NOTE               = "CELSIUS = 100*V5plus - 0.100*DN - 273.2"
END_OBJECT           = COLUMN
OBJECT               = COLUMN
  NAME               = RADHIGHSENS
  COLUMN_NUMBER      = 18
  START_BYTE         = 55
  BYTES              = 2
  DATA_TYPE          = MSB_UNSIGNED_INTEGER
  UNIT               = "N/A"
  MINIMUM            = 0
  MAXIMUM            = 4095
  DESCRIPTION        = "Radiation Monitor Scalar Output--High Sensitivity."
  NOTE               = "RADS = 0.00002*((DN+8)/16)"
END_OBJECT           = COLUMN
OBJECT               = COLUMN
  NAME               = RADMEDSENS
  COLUMN_NUMBER      = 19
  START_BYTE         = 57
  BYTES              = 2
  DATA_TYPE          = MSB_UNSIGNED_INTEGER
  UNIT               = "N/A"
  MINIMUM            = 0
  MAXIMUM            = 4095
  DESCRIPTION        = "Radiation Monitor Scalar Output--Medium Sensitivity."
  NOTE               = "RADS = 0.00512*((DN+8)/16)"
END_OBJECT           = COLUMN
OBJECT               = COLUMN
  NAME               = RADLOWSENS
  COLUMN_NUMBER      = 20
  START_BYTE         = 59
  BYTES              = 2
  DATA_TYPE          = MSB_UNSIGNED_INTEGER
  UNIT               = "N/A"
  MINIMUM            = 0
  MAXIMUM            = 4095
  DESCRIPTION        = "Radiation Monitor Scalar Output--Low Sensitivity."
  NOTE               = "RADS = 1.31*((DN+8)/16)"
END_OBJECT           = COLUMN
OBJECT               = COLUMN
  NAME               = TPRT
  COLUMN_NUMBER      = 21
  START_BYTE         = 61
  BYTES              = 2
  DATA_TYPE          = MSB_UNSIGNED_INTEGER
  UNIT               = "N/A"
  MINIMUM            = 0
  MAXIMUM            = 4095
  DESCRIPTION        = "Temperature Monitor Value--Reference Location,
                       Instrument Chassis (ground test only)."
  NOTE               = "CELSIUS = 0.1299*(4*DN-1E4)/(5-DN/1E3)"
END_OBJECT           = COLUMN
OBJECT               = COLUMN
  NAME               = PURGE
  COLUMN_NUMBER      = 22
  START_BYTE         = 63
  BYTES              = 2
  DATA_TYPE          = MSB_UNSIGNED_INTEGER
  UNIT               = "N/A"
  MINIMUM            = 0
  MAXIMUM            = 4095
  DESCRIPTION        = "GN2 Purge Flow Rate Monitor Value (ground test only)
                       (in UNITS formula V5plus in volts, Tref in Celsius)."
  NOTE               = "CU FT/HR = DN-0.371*V5plus+19*(Tref-20)"
END_OBJECT           = COLUMN