OBJECT = COLUMN NAME = HEADER COLUMN_NUMBER = 1 START_BYTE = 1 BYTES = 12 ^STRUCTURE = "CRAT_L0_HDR.FMT" DATA_TYPE = BIT_STRING DESCRIPTION = "CCSDS Primary and Secondary Headers, ApId = 122." END_OBJECT = COLUMN OBJECT = COLUMN NAME = CRATVERFPGA COLUMN_NUMBER = 2 START_BYTE = 13 BYTES = 2 DATA_TYPE = BIT_STRING DESCRIPTION = "FPGA Revision Code." OBJECT = BIT_COLUMN NAME = FPGA_SN COLUMN_NUMBER = 1 START_BIT = 1 BITS = 4 BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER MINIMUM = 0 MAXIMUM = 15 DESCRIPTION = "FPGA Revision Code." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = "N/A" COLUMN_NUMBER = 2 START_BIT = 5 BITS = 12 BIT_DATA_TYPE = "N/A" DESCRIPTION = "Unused." END_OBJECT = BIT_COLUMN END_OBJECT = COLUMN OBJECT = COLUMN NAME = V5DIGITAL COLUMN_NUMBER = 3 START_BYTE = 15 BYTES = 2 DATA_TYPE = MSB_UNSIGNED_INTEGER UNIT = "N/A" MINIMUM = 0 MAXIMUM = 4095 DESCRIPTION = "+5VDC Digital Regulated Voltage Monitor Value." NOTE = "VOLTS = 0.00200*DN" END_OBJECT = COLUMN OBJECT = COLUMN NAME = CRATV5PLUS COLUMN_NUMBER = 4 START_BYTE = 17 BYTES = 2 DATA_TYPE = BIT_STRING DESCRIPTION = "Analog Voltage Status Indicator and +5VDC Analog Regulated Voltage Monitor Value." OBJECT = BIT_COLUMN NAME = VANALOGERR COLUMN_NUMBER = 1 START_BIT = 1 BITS = 4 BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER MINIMUM = 0 MAXIMUM = 15 DESCRIPTION = "Analog Voltage Status Indicator (0 = on; 15 = off, remaining H/K invalid)." END_OBJECT = BIT_COLUMN OBJECT = BIT_COLUMN NAME = V5PLUS COLUMN_NUMBER = 2 START_BIT = 5 BITS = 12 BIT_DATA_TYPE = MSB_UNSIGNED_INTEGER UNIT = "N/A" MINIMUM = 0 MAXIMUM = 4095 DESCRIPTION = "+5VDC Analog Regulated Voltage Monitor Value." NOTE = "VOLTS = 0.00200*DN" END_OBJECT = BIT_COLUMN END_OBJECT = COLUMN OBJECT = COLUMN NAME = V5NEG COLUMN_NUMBER = 5 START_BYTE = 19 BYTES = 2 DATA_TYPE = MSB_UNSIGNED_INTEGER UNIT = "N/A" MINIMUM = 0 MAXIMUM = 4095 DESCRIPTION = "-5VDC Analog Regulated Voltage Monitor Value." NOTE = "VOLTS = -0.00201*DN" END_OBJECT = COLUMN OBJECT = COLUMN NAME = "N/A" COLUMN_NUMBER = 6 START_BYTE = 21 BYTES = 2 DATA_TYPE = "N/A" DESCRIPTION = "Unused." END_OBJECT = COLUMN OBJECT = COLUMN NAME = BIASCURRENT COLUMN_NUMBER = 7 START_BYTE = 23 BYTES = 12 ITEM_BYTES = 2 ITEMS = 6 DATA_TYPE = MSB_UNSIGNED_INTEGER UNIT = "N/A" MINIMUM = 0 MAXIMUM = 4095 DESCRIPTION = "Detector Bias Current Monitor Values." NOTE = "AMPS = 5E-10*DN, 5E-9*DN, 5E-10*DN, ..." END_OBJECT = COLUMN OBJECT = COLUMN NAME = BIASVOLTTHIN COLUMN_NUMBER = 8 START_BYTE = 35 BYTES = 2 DATA_TYPE = MSB_UNSIGNED_INTEGER UNIT = "N/A" MINIMUM = 0 MAXIMUM = 4095 DESCRIPTION = "Thin Detector (D1, D3, D5) Bias Monitor Value." NOTE = "VOLTS = 0.101*DN" END_OBJECT = COLUMN OBJECT = COLUMN NAME = BIASVOLTTHICK COLUMN_NUMBER = 9 START_BYTE = 37 BYTES = 2 DATA_TYPE = MSB_UNSIGNED_INTEGER UNIT = "N/A" MINIMUM = 0 MAXIMUM = 4095 DESCRIPTION = "Thick Detector (D2, D4, D6) Bias Monitor Value." NOTE = "VOLTS = 0.101*DN" END_OBJECT = COLUMN OBJECT = COLUMN NAME = CALAMP COLUMN_NUMBER = 10 START_BYTE = 39 BYTES = 2 DATA_TYPE = MSB_UNSIGNED_INTEGER UNIT = "N/A" MINIMUM = 0 MAXIMUM = 4095 DESCRIPTION = "Internal Calibration Pulser Amplitude Monitor Value." NOTE = "VOLTS = 0.00100*DN" END_OBJECT = COLUMN OBJECT = COLUMN NAME = LLDTHIN COLUMN_NUMBER = 11 START_BYTE = 41 BYTES = 2 DATA_TYPE = MSB_UNSIGNED_INTEGER UNIT = "N/A" MINIMUM = 0 MAXIMUM = 4095 DESCRIPTION = "LLD Amplitude Monitor Value--Thin Detectors (D1, D3, D5)." NOTE = "VOLTS = 0.000124*DN - 0.124" END_OBJECT = COLUMN OBJECT = COLUMN NAME = LLDTHICK COLUMN_NUMBER = 12 START_BYTE = 43 BYTES = 2 DATA_TYPE = MSB_UNSIGNED_INTEGER UNIT = "N/A" MINIMUM = 0 MAXIMUM = 4095 DESCRIPTION = "LLD Amplitude Monitor Value--Thick Detectors (D2, D4, D6)." NOTE = "VOLTS = 0.000124*DN - 0.124" END_OBJECT = COLUMN OBJECT = COLUMN NAME = TTELESCOPE COLUMN_NUMBER = 13 START_BYTE = 45 BYTES = 2 DATA_TYPE = MSB_UNSIGNED_INTEGER UNIT = "N/A" MINIMUM = 0 MAXIMUM = 4095 DESCRIPTION = "Temperature Monitor Value--Telescope Assembly (in UNITS formula V5plus in volts)." NOTE = "CELSIUS = 100*V5plus - 0.100*DN - 273.2" END_OBJECT = COLUMN OBJECT = COLUMN NAME = TANALOG COLUMN_NUMBER = 14 START_BYTE = 47 BYTES = 2 DATA_TYPE = MSB_UNSIGNED_INTEGER UNIT = "N/A" MINIMUM = 0 MAXIMUM = 4095 DESCRIPTION = "Temperature Monitor Value--Analog Electronics Board (in UNITS formula V5plus in volts)." NOTE = "CELSIUS = 100*V5plus - 0.100*DN - 273.2" END_OBJECT = COLUMN OBJECT = COLUMN NAME = TDIGITAL COLUMN_NUMBER = 15 START_BYTE = 49 BYTES = 2 DATA_TYPE = MSB_UNSIGNED_INTEGER UNIT = "N/A" MINIMUM = 0 MAXIMUM = 4095 DESCRIPTION = "Temperature Monitor Value--Digital Electronics Board (in UNITS formula V5plus in volts)." NOTE = "CELSIUS = 100*V5plus - 0.100*DN - 273.2" END_OBJECT = COLUMN OBJECT = COLUMN NAME = TPOWER COLUMN_NUMBER = 16 START_BYTE = 51 BYTES = 2 DATA_TYPE = MSB_UNSIGNED_INTEGER UNIT = "N/A" MINIMUM = 0 MAXIMUM = 4095 DESCRIPTION = "Temperature Monitor Value--Power Supply (in UNITS formula V5plus in volts)." NOTE = "CELSIUS = 100*V5plus - 0.100*DN - 273.2" END_OBJECT = COLUMN OBJECT = COLUMN NAME = TREF COLUMN_NUMBER = 17 START_BYTE = 53 BYTES = 2 DATA_TYPE = MSB_UNSIGNED_INTEGER UNIT = "N/A" MINIMUM = 0 MAXIMUM = 4095 DESCRIPTION = "Temperature Monitor Value--Reference Location, Telescope Housing Wall (in UNITS formula V5plus in volts)." NOTE = "CELSIUS = 100*V5plus - 0.100*DN - 273.2" END_OBJECT = COLUMN OBJECT = COLUMN NAME = RADHIGHSENS COLUMN_NUMBER = 18 START_BYTE = 55 BYTES = 2 DATA_TYPE = MSB_UNSIGNED_INTEGER UNIT = "N/A" MINIMUM = 0 MAXIMUM = 4095 DESCRIPTION = "Radiation Monitor Scalar Output--High Sensitivity." NOTE = "RADS = 0.00002*((DN+8)/16)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = RADMEDSENS COLUMN_NUMBER = 19 START_BYTE = 57 BYTES = 2 DATA_TYPE = MSB_UNSIGNED_INTEGER UNIT = "N/A" MINIMUM = 0 MAXIMUM = 4095 DESCRIPTION = "Radiation Monitor Scalar Output--Medium Sensitivity." NOTE = "RADS = 0.00512*((DN+8)/16)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = RADLOWSENS COLUMN_NUMBER = 20 START_BYTE = 59 BYTES = 2 DATA_TYPE = MSB_UNSIGNED_INTEGER UNIT = "N/A" MINIMUM = 0 MAXIMUM = 4095 DESCRIPTION = "Radiation Monitor Scalar Output--Low Sensitivity." NOTE = "RADS = 1.31*((DN+8)/16)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = TPRT COLUMN_NUMBER = 21 START_BYTE = 61 BYTES = 2 DATA_TYPE = MSB_UNSIGNED_INTEGER UNIT = "N/A" MINIMUM = 0 MAXIMUM = 4095 DESCRIPTION = "Temperature Monitor Value--Reference Location, Instrument Chassis (ground test only)." NOTE = "CELSIUS = 0.1299*(4*DN-1E4)/(5-DN/1E3)" END_OBJECT = COLUMN OBJECT = COLUMN NAME = PURGE COLUMN_NUMBER = 22 START_BYTE = 63 BYTES = 2 DATA_TYPE = MSB_UNSIGNED_INTEGER UNIT = "N/A" MINIMUM = 0 MAXIMUM = 4095 DESCRIPTION = "GN2 Purge Flow Rate Monitor Value (ground test only) (in UNITS formula V5plus in volts, Tref in Celsius)." NOTE = "CU FT/HR = DN-0.371*V5plus+19*(Tref-20)" END_OBJECT = COLUMN |