Download this file

PDS_VERSION_ID            = PDS3

RECORD_TYPE               = STREAM
FILE_RECORDS              = 23

START_TIME                = 2012-092T00:00
STOP_TIME                 = 2012-093T00:00

SPACECRAFT_CLOCK_START_COUNT = "1/1711932686:192"
SPACECRAFT_CLOCK_STOP_COUNT = "1/1712019087:76"

^HEADER                   = ("LACCAVG0_1HR_2012092_01.CSV", 1 ❮BYTES❯)
^SPREADSHEET              = ("LACCAVG0_1HR_2012092_01.CSV", 1279 ❮BYTES❯)
MD5_CHECKSUM              = "b8f1d4eb50f4b25147c4af0011b2ab06"

PRODUCT_TYPE              = "DATA"
DATA_SET_ID               = "CO-S-MIMI-4-LEMMS-CALIB-V1.0"
PRODUCT_ID                = "LACCAVG0_1HR_2012092"
STANDARD_DATA_PRODUCT_ID  = "LEMMS_ACC_AVG_1HR"
PRODUCT_VERSION_ID        = "01"
INSTRUMENT_HOST_NAME      = "CASSINI ORBITER"
INSTRUMENT_HOST_ID        = "CO"
TARGET_NAME               = "SATURN"
INSTRUMENT_NAME           = "MAGNETOSPHERIC IMAGING INSTRUMENT"
INSTRUMENT_ID             = "MIMI"
PRODUCT_CREATION_TIME     = 2013-078T09:29:36
DESCRIPTION               = "The data columns contain 1 hour averages of
    LEMMS accumulator rates data. The data are averaged by first defining
    fixed one hour intervals throughout the day and then averaging any data
    points that fall in the intervals. If an interval contains no data, it is
    still listed in the file, but all data intensity values will be fill. The
    fill value for data in this file is -1.0E38.

    These data are background subtracted, and thus occasionally there will be
    negative values when the count rate falls below the background level.
    Also, the uncertainties are based on the counting statistics, and thus
    because of the background subtraction, the uncertainties can be larger
    than the data value.

    The background levels change over time and each channel's background level
    as a function of time in counts/sec is listed in the MIMI calibration file
    (described in the MIMI Data User Guide, the SIS for this dataset, and also
    in SIS for the uncalibrated MIMI data).

    There are four types of channels included in these averages. The channels
    A0 through A8 are measured by the low energy end of LEMMS (the Low Energy
    Telescope, or LET), and for protons these channels have an energy range of
    27 to 4000 keV. The P1 through P9 channels capture protons as measured by
    the LEMMS High Energy Telescope (HET) and have an energy range of 1 to 60
    MeV. Channels C0 through C7 measure electrons, and have an energy of 20 to
    900 keV. The E0 through E4 channels are also electrons covering the 150 to
    3000 keV range. The MIMI instrument paper describes these channels, as
    does the MIMI Data User Guide.

    The file header and leading columns of the file are present to make the
    format consistent with other MIMI data in the PDS. Note that much of the
    values for the leading columns are -1, indicating that they do not have
    useful values, but their presence allows this file to be parsed by the
    same code that reads other MIMI PDS data. The first column is always the
    string 'sci', the next column is a UTC string, and then these prefix
    columns have no data in them but are just there to preserve the format:
    UTC   SCLOCK   Start_Ephemeris_s End_Ephemeris_s   Spin_Counter   Sector  
     Start_Sector_Sclock_major  Subsector   Microsectors_Covered Spin_Period_s
     Staring  Sensor_Bitrate

    Just before the data columns are three columns giving the position of the
    Cassini spacecraft relavtive to Saturn in the SZS frame. The position is
    given for the middle of the time interval. The units are Saturn radii
    (60268 km) and the SZS frame is defined as: +Z is Saturn spin axis, +Y is
    +Z cross the Saturn-Sun line, and +X is +Y cross +Z."

OBJECT                    = HEADER
  RECORDS                 = 1
  BYTES                   = 759
  HEADER_TYPE             = SPREADSHEET
  DESCRIPTION             = "column names for the fields"
END_OBJECT                = HEADER


OBJECT                    = SPREADSHEET
  FIELDS                  = 79
  FIELD_DELIMITER         = COMMA
  ROW_BYTES               = 1610
  ROWS                    = 23

  OBJECT                  = FIELD
    NAME                  = "Purpose"
    DATA_TYPE             = "CHARACTER"
    FIELD_NUMBER          = 1
    BYTES                 = 3
    DESCRIPTION           = "indicates that this row contains science
    data"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "UTC"
    DATA_TYPE             = "TIME"
    FIELD_NUMBER          = 2
    BYTES                 = 21
    DESCRIPTION           = "midpoint time of the averaging interval as a
    UTC string in ISO 8601 format"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "SCLOCK"
    DATA_TYPE             = "TIME"
    FIELD_NUMBER          = 3
    BYTES                 = 16
    DESCRIPTION           = "midpoint time of the averaging interval as a
    spacecraft clock string; SCLOCK values are recorded as P/NNNNNNNNNN.FFF
    where P is the partition number, NNNNNNNNNN is roughly the number of
    seconds since the start of the partition, and FFF is the number of ticks.
    Each tick is roughly 1/256 of a second."
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Start_Ephemeris_s"
    UNIT                  = "SECONDS"
    DATA_TYPE             = "TIME"
    FIELD_NUMBER          = 4
    BYTES                 = 22
    DESCRIPTION           = "start time of the averaging interval in
    ephemeris time (TDB seconds past the J2000 epoch)"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "End_Ephemeris_s"
    UNIT                  = "SECONDS"
    DATA_TYPE             = "TIME"
    FIELD_NUMBER          = 5
    BYTES                 = 22
    DESCRIPTION           = "end time of the averaging interval in
    ephemeris time (TDB seconds past the J2000 epoch)"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Spin_Counter"
    UNIT                  = "N/A"
    DATA_TYPE             = "N/A"
    FIELD_NUMBER          = 6
    BYTES                 = 3
    DESCRIPTION           = "unused field in this file"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Sector"
    UNIT                  = "N/A"
    DATA_TYPE             = "N/A"
    FIELD_NUMBER          = 7
    BYTES                 = 3
    DESCRIPTION           = "unused field in this file"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Start_Sector_Sclock_major"
    UNIT                  = "N/A"
    DATA_TYPE             = "N/A"
    FIELD_NUMBER          = 8
    BYTES                 = 3
    DESCRIPTION           = "unused field in this file"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Subsector"
    UNIT                  = "N/A"
    DATA_TYPE             = "N/A"
    FIELD_NUMBER          = 9
    BYTES                 = 3
    DESCRIPTION           = "unused field in this file"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Microsectors_Covered"
    UNIT                  = "N/A"
    DATA_TYPE             = "N/A"
    FIELD_NUMBER          = 10
    BYTES                 = 3
    DESCRIPTION           = "unused field in this file"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Spin_Period_s"
    UNIT                  = "N/A"
    DATA_TYPE             = "N/A"
    FIELD_NUMBER          = 11
    BYTES                 = 3
    DESCRIPTION           = "unused field in this file"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Staring"
    UNIT                  = "N/A"
    DATA_TYPE             = "N/A"
    FIELD_NUMBER          = 12
    BYTES                 = 3
    DESCRIPTION           = "unused field in this file"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "Sensor_Bitrate"
    UNIT                  = "N/A"
    DATA_TYPE             = "N/A"
    FIELD_NUMBER          = 13
    BYTES                 = 3
    DESCRIPTION           = "unused field in this file"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "SZS_x"
    UNIT                  = "SATURN_RADII"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 13
    BYTES                 = 13
    DESCRIPTION           = "SZS x component of the position of Cassini
    relative to Saturn"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "SZS_y"
    UNIT                  = "SATURN_RADII"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 14
    BYTES                 = 13
    DESCRIPTION           = "SZS y component of the position of Cassini
    relative to Saturn"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "SZS_z"
    UNIT                  = "SATURN_RADII"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 15
    BYTES                 = 13
    DESCRIPTION           = "SZS z component of the position of Cassini
    relative to Saturn"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "MinSunAngle"
    UNIT                  = "DEGREES"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 16
    BYTES                 = 7
    DESCRIPTION           = "minimum angle between the LEMMS LET boresight
    direction and the SC-to-Sun line during the averaging interval; this helps
    users determine the possibility of light contamination; the most
    conservative estimate is 60 degrees, but sometimes much smaller angles
    such as 20 degrees are still ok"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "A0"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 18
    BYTES                 = 17
    DESCRIPTION           = "intensity for channel A0; energy range for
    this channel is 27 to 35 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "A0_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 20
    BYTES                 = 19
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "A1"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 22
    BYTES                 = 21
    DESCRIPTION           = "intensity for channel A1; energy range for
    this channel is 35 to 56 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "A1_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 24
    BYTES                 = 23
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "A2"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 26
    BYTES                 = 25
    DESCRIPTION           = "intensity for channel A2; energy range for
    this channel is 56 to 106 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "A2_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 28
    BYTES                 = 27
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "A3"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 30
    BYTES                 = 29
    DESCRIPTION           = "intensity for channel A3; energy range for
    this channel is 106 to 255 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "A3_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 32
    BYTES                 = 31
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "A4"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 34
    BYTES                 = 33
    DESCRIPTION           = "intensity for channel A4; energy range for
    this channel is 255 to 506 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "A4_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 36
    BYTES                 = 35
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "A5"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 38
    BYTES                 = 37
    DESCRIPTION           = "intensity for channel A5; energy range for
    this channel is 506 to 805 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "A5_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 40
    BYTES                 = 39
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "A6"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 42
    BYTES                 = 41
    DESCRIPTION           = "intensity for channel A6; energy range for
    this channel is 805 to 1600 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "A6_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 44
    BYTES                 = 43
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "A7"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 46
    BYTES                 = 45
    DESCRIPTION           = "intensity for channel A7; energy range for
    this channel is 1615 to 4000 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "A7_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 48
    BYTES                 = 47
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "A8"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 50
    BYTES                 = 49
    DESCRIPTION           = "intensity for channel A8; energy range for
    this channel is 1270 to 3930 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "A8_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 52
    BYTES                 = 51
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "C0"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 54
    BYTES                 = 53
    DESCRIPTION           = "intensity for channel C0; energy range for
    this channel is 18 to 40 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "C0_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 56
    BYTES                 = 55
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "C1"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 58
    BYTES                 = 57
    DESCRIPTION           = "intensity for channel C1; energy range for
    this channel is 27 to 48 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "C1_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 60
    BYTES                 = 59
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "C2"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 62
    BYTES                 = 61
    DESCRIPTION           = "intensity for channel C2; energy range for
    this channel is 41 to 60 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "C2_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 64
    BYTES                 = 63
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "C3"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 66
    BYTES                 = 65
    DESCRIPTION           = "intensity for channel C3; energy range for
    this channel is 56 to 100 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "C3_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 68
    BYTES                 = 67
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "C4"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 70
    BYTES                 = 69
    DESCRIPTION           = "intensity for channel C4; energy range for
    this channel is 92 to 183 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "C4_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 72
    BYTES                 = 71
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "C5"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 74
    BYTES                 = 73
    DESCRIPTION           = "intensity for channel C5; energy range for
    this channel is 175 to 300 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "C5_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 76
    BYTES                 = 75
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "C6"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 78
    BYTES                 = 77
    DESCRIPTION           = "intensity for channel C6; energy range for
    this channel is 265 to 550 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "C6_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 80
    BYTES                 = 79
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "C7"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 82
    BYTES                 = 81
    DESCRIPTION           = "intensity for channel C7; energy range for
    this channel is 510 to 832 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "C7_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 84
    BYTES                 = 83
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "E0"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 86
    BYTES                 = 85
    DESCRIPTION           = "intensity for channel E0; energy range for
    this channel is 110 to 365 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "E0_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 88
    BYTES                 = 87
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "E1"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 90
    BYTES                 = 89
    DESCRIPTION           = "intensity for channel E1; energy range for
    this channel is 220 to 485 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "E1_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 92
    BYTES                 = 91
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "E2"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 94
    BYTES                 = 93
    DESCRIPTION           = "intensity for channel E2; energy range for
    this channel is 340 to 1350 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "E2_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 96
    BYTES                 = 95
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "E3"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 98
    BYTES                 = 97
    DESCRIPTION           = "intensity for channel E3; energy range for
    this channel is 600 to 4950 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "E3_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 100
    BYTES                 = 99
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "E4"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 102
    BYTES                 = 101
    DESCRIPTION           = "intensity for channel E4; energy range for
    this channel is 790 to 4750 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "E4_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 104
    BYTES                 = 103
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "P1"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 106
    BYTES                 = 105
    DESCRIPTION           = "intensity for channel P1; energy range for
    this channel is 1424 to 2278 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "P1_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 108
    BYTES                 = 107
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "P2"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 110
    BYTES                 = 109
    DESCRIPTION           = "intensity for channel P2; energy range for
    this channel is 2280 to 4492 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "P2_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 112
    BYTES                 = 111
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "P3"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 114
    BYTES                 = 113
    DESCRIPTION           = "intensity for channel P3; energy range for
    this channel is 4491 to 5744 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "P3_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 116
    BYTES                 = 115
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "P4"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 118
    BYTES                 = 117
    DESCRIPTION           = "intensity for channel P4; energy range for
    this channel is 13200 to 25400 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "P4_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 120
    BYTES                 = 119
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "P5"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 122
    BYTES                 = 121
    DESCRIPTION           = "intensity for channel P5; energy range for
    this channel is 8311 to 11449 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "P5_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 124
    BYTES                 = 123
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "P6"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 126
    BYTES                 = 125
    DESCRIPTION           = "intensity for channel P6; energy range for
    this channel is 11474 to 13433 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "P6_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 128
    BYTES                 = 127
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "P7"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 130
    BYTES                 = 129
    DESCRIPTION           = "intensity for channel P7; energy range for
    this channel is 12101 to 58902 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "P7_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 132
    BYTES                 = 131
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "P8"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 134
    BYTES                 = 133
    DESCRIPTION           = "intensity for channel P8; energy range for
    this channel is 25185 to 59000 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "P8_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 136
    BYTES                 = 135
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "P9"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 138
    BYTES                 = 137
    DESCRIPTION           = "intensity for channel P9; energy range for
    this channel is 58650 to 158700 keV"
  END_OBJECT              = FIELD

  OBJECT                  = FIELD
    NAME                  = "P9_UNCERT"
    UNIT                  = "counts/sec/ster/cm^2/keV"
    DATA_TYPE             = "ASCII_REAL"
    FIELD_NUMBER          = 140
    BYTES                 = 139
    DESCRIPTION           = "uncertainty value for this channel; these are
    statistical uncertainties only"
  END_OBJECT              = FIELD

END_OBJECT                = SPREADSHEET

END