Download this file |
/* */ /* 14-Sep-2004 D. Gell Updates Per J. Mafi */ /* Added FIELD_NUMBER keyword */ /* */ /*******************************************************************/ OBJECT = FIELD FIELD_NUMBER = 1 NAME = "nOriginalPacketID" BYTES = 10 DATA_TYPE = ASCII_INTEGER FORMAT = "I10" DESCRIPTION = "The unique database ID of the packet" END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 2 NAME = "nEventID" BYTES = 10 DATA_TYPE = ASCII_INTEGER FORMAT = "I10" DESCRIPTION = "The ID that references the INMSDB data event the telemetry packet belongs to" END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 3 NAME = "nAssocSciOrigpacketID" BYTES = 10 DATA_TYPE = ASCII_INTEGER FORMAT = "I10" DESCRIPTION = "The associated science packet (the nearest science packet chronologically) for this HK packet. ** Not currently used." END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 4 NAME = "tSclkTime" BYTES = 23 DATA_TYPE = CHARACTER FORMAT = "A23" DESCRIPTION = "The spacecraft clock time of the packet - does not include milliseconds (see NSCLKMillis below for milliseconds)" END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 5 NAME = "dSclkRaw" BYTES = 15 DATA_TYPE = ASCII_REAL FORMAT = "F15.1" DESCRIPTION = "The raw spacecraft clock time that TSCLKTIME and NSCLKMillis were generated from" END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 6 NAME = "tErtTime" BYTES = 23 DATA_TYPE = CHARACTER FORMAT = "A23" DESCRIPTION = "The Earth Receive Time - the time the packet was received from a NASA DSN station" END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 7 NAME = "tProcessedTime" BYTES = 23 DATA_TYPE = CHARACTER FORMAT = "A23" DESCRIPTION = "The UTC time the packet was processed by the INMS data system" END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 8 NAME = "sMode" BYTES = 10 DATA_TYPE = CHARACTER FORMAT = "A10" DESCRIPTION = "Packet mode, indicates if the packet is data or synthetic test data" END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 9 NAME = "bValid" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Indicates that the packet is a valid packet" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 10 NAME = "nInstMode" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Specifies the instrument operating mode, " VALID_MINIMUM = 0 VALID_MAXIMUM = 7 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 11 NAME = "nSequenceTable" BYTES = 2 DATA_TYPE = ASCII_INTEGER FORMAT = "I2" DESCRIPTION = "Sequence table number" VALID_MINIMUM = 0 VALID_MAXIMUM = 31 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 12 NAME = "nCycleIndex" BYTES = 2 DATA_TYPE = ASCII_INTEGER FORMAT = "I2" DESCRIPTION = "Index of the cycle table entry" VALID_MINIMUM = 0 VALID_MAXIMUM = 15 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 13 NAME = "nScanIndex" BYTES = 2 DATA_TYPE = ASCII_INTEGER FORMAT = "I2" DESCRIPTION = "The number of the scan within the cycle" VALID_MINIMUM = 0 VALID_MAXIMUM = 15 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 14 NAME = "nElapsedTime" BYTES = 5 DATA_TYPE = ASCII_INTEGER FORMAT = "I5" DESCRIPTION = "The time elapsed since the start of the current sequence table" UNIT = "s" VALID_MINIMUM = 0 VALID_MAXIMUM = 65535 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 15 NAME = "nCycleTable" BYTES = 2 DATA_TYPE = ASCII_INTEGER FORMAT = "I2" DESCRIPTION = "Cycle table number" VALID_MINIMUM = 0 VALID_MAXIMUM = 63 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 16 NAME = "nspare1" BYTES = 17 DATA_TYPE = ASCII_INTEGER FORMAT = "I2" DESCRIPTION = "2-bit field. LSB=ScanIndex MSB, MSB=CycleIndex MSB" END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 17 NAME = "nDataSumN" BYTES = 3 DATA_TYPE = ASCII_INTEGER FORMAT = "I3" DESCRIPTION = "Number of mass scans being co-added to reduce telemetry requirements" VALID_MINIMUM = 0 VALID_MAXIMUM = 255 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 18 NAME = "nThermStatus" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Thermistor test status. Performed before pressure BA test. Only valid prior to cover removal." VALID_MINIMUM = 0 VALID_MAXIMUM = 3 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 19 NAME = "nThermDelta" BYTES = 4 DATA_TYPE = ASCII_INTEGER FORMAT = "I4" DESCRIPTION = "Thermistor pressure AMUX value. Amux ID=49. Valid only prior to cover removal." VALID_MINIMUM = -512 VALID_MAXIMUM = 512 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 20 NAME = "nFswVersion" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I3" DESCRIPTION = "Reports the flight software version" END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 21 NAME = "nBaStatus" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Pressure test status, valid only prior to cover removal" VALID_MINIMUM = 0 VALID_MAXIMUM = 3 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 22 NAME = "nBaStep" BYTES = 2 DATA_TYPE = ASCII_INTEGER FORMAT = "I2" DESCRIPTION = "BA DAC emission value. Valid only prior to cover removal." VALID_MINIMUM = 0 VALID_MAXIMUM = 15 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 23 NAME = "nBaValue" BYTES = 2 DATA_TYPE = ASCII_INTEGER FORMAT = "I2" DESCRIPTION = "Pressure at end of test. Valid only prior to cover removal" VALID_MINIMUM = 0 VALID_MAXIMUM = 15 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 24 NAME = "nTcReceived" BYTES = 3 DATA_TYPE = ASCII_INTEGER FORMAT = "I3" DESCRIPTION = "Number of telecommands received" VALID_MINIMUM = 0 VALID_MAXIMUM = 255 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 25 NAME = "nAlfReceived" BYTES = 3 DATA_TYPE = ASCII_INTEGER FORMAT = "I3" DESCRIPTION = "Indicates a BIU bus error" VALID_MINIMUM = 0 VALID_MAXIMUM = 255 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 26 NAME = "nAlfRejected" BYTES = 2 DATA_TYPE = ASCII_INTEGER FORMAT = "I2" DESCRIPTION = "Indicates a 1750 machine error" VALID_MINIMUM = 0 VALID_MAXIMUM = 15 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 27 NAME = "nTcRejected" BYTES = 2 DATA_TYPE = ASCII_INTEGER FORMAT = "I2" DESCRIPTION = "Number of telecommads rejected" VALID_MINIMUM = 0 VALID_MAXIMUM = 15 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 28 NAME = "nInstTmMode" BYTES = 3 DATA_TYPE = ASCII_INTEGER FORMAT = "I3" DESCRIPTION = "Telmetry mode index" VALID_MINIMUM = 0 VALID_MAXIMUM = 255 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 29 NAME = "nBiuSpare1" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Readback of BIU discretes 6 and 7" VALID_MINIMUM = 0 VALID_MAXIMUM = 3 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 30 NAME = "bTgordt" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Readback of Flight computer boot mode descrete" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 31 NAME = "bAlfOverInhibit" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Readback of ALF override inhibit discrete" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 32 NAME = "bAlfBootEnable" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Readback of ALF boot enable discrete" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 33 NAME = "bDefSciEnable" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Readback of default science enable descrete" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 34 NAME = "bBiuSleep" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "readback of sleep discrete" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 35 NAME = "bBiuPord0" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "readback of BIU discrete 0" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 36 NAME = "bHkFull" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "BIU error flag set when houskeeping tm buffer is full" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 37 NAME = "bHkSsysf" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "BIU error flag set when subsystem fail bit is set in 1553 status word" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 38 NAME = "bHkMsgError" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "BIU error flag set when message error bit is set in 1553 status word" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 39 NAME = "bTmScError" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "BIU error flag set when the number words expected in 1553 receive sub-address 29 is incorrect" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 40 NAME = "bStTblError" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "BIU error flag set when the number words expected in 1553 receive sub-address 19 is incorrect" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 41 NAME = "bAncbcError" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "BIU error flag set when the number words expected in 1553 receive sub-address 10 is incorrect" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 42 NAME = "bbiuspare2" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "spare, always 0" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 43 NAME = "bRtiSfail" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Set when no RTIs have been received for 2 seconds" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 44 NAME = "bFil1On" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "State of primary open source filament" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 45 NAME = "bFil2On" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "State of secondary open source filament" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 46 NAME = "bFil3On" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "State of primary closed source filament" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 47 NAME = "bFil4On" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "State of secondary closed source filament" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 48 NAME = "bDconSpare1" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "spare" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 49 NAME = "bFil6On" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "State of BA pressure gauge filament" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 50 NAME = "nDconSpare2" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "spare" VALID_MINIMUM = 0 VALID_MAXIMUM = 3 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 51 NAME = "bBiuWdx" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "BIU watchdog timer status, 1(ok) 0(expired)" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 52 NAME = "bBiuFt" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "BIU write status, set to 0 when a BIU bus timeout is detected in boot code" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 53 NAME = "bFcft" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "BIU write status, set to 0 when a CPU Machine Error is detected in boot code" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 54 NAME = "bFctGo" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "BIU write status, set when TGO reset indicator latch is set on bootup. Always set to 0 in TM." VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 55 NAME = "bFcillad" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "BIU write status, set to 0 when CPU accesses an illegal address. Always set to 0 in TM." VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 56 NAME = "bFcnpu" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "BIU write status, set to 1 when CPU completes a normal power up. Always set to 0 in TM." VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 57 NAME = "bFcsuren" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "BIU write status, set to 0 when CPU start-up RAM is enabled. Always set to 0 in TM." VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 58 NAME = "bBiuDtsLoaded" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "BIU write status, set to 1 when BIU descriptor table is loaded on bootup." VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 59 NAME = "d1emission" BYTES = 7 DATA_TYPE = ASCII_REAL FORMAT = "F7.4" DESCRIPTION = "Emission Current of primary open source filament" UNIT = "uA" VALID_MINIMUM = -0.5 VALID_MAXIMUM = 25.75 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 60 NAME = "d2emission" BYTES = 8 DATA_TYPE = ASCII_REAL FORMAT = "F8.5" DESCRIPTION = "Emission Current of secondary open source filament" UNIT = "uA" VALID_MINIMUM = 0.05 VALID_MAXIMUM = 25.75 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 61 NAME = "dImon1" BYTES = 8 DATA_TYPE = ASCII_REAL FORMAT = "F8.6" DESCRIPTION = "Input current" UNIT = "A" VALID_MINIMUM = 0.0 VALID_MAXIMUM = 1.75 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 62 NAME = "dGround1" BYTES = 5 DATA_TYPE = ASCII_REAL FORMAT = "F5.2" DESCRIPTION = "Ground reference voltage" UNIT = "V" VALID_MINIMUM = -0.05 VALID_MAXIMUM = 5.1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 63 NAME = "d1Current" BYTES = 8 DATA_TYPE = ASCII_REAL FORMAT = "F8.5" DESCRIPTION = "Primary open source filament current" UNIT = "A" VALID_MINIMUM = -0.1 VALID_MAXIMUM = 1.5 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 64 NAME = "d2Current" BYTES = 8 DATA_TYPE = ASCII_REAL FORMAT = "F8.5" DESCRIPTION = "Secondary open source filament current" UNIT = "A" VALID_MINIMUM = -0.1 VALID_MAXIMUM = 1.5 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 65 NAME = "d1Target" BYTES = 8 DATA_TYPE = ASCII_REAL FORMAT = "F8.5" DESCRIPTION = "Primary open source anode current" UNIT = "uA" VALID_MINIMUM = -0.5 VALID_MAXIMUM = 27.75 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 66 NAME = "d2Target" BYTES = 8 DATA_TYPE = ASCII_REAL FORMAT = "F8.5" DESCRIPTION = "Secondary open source anode current" UNIT = "uA" VALID_MINIMUM = -0.5 VALID_MAXIMUM = 27.75 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 67 NAME = "d1Bias50" BYTES = 5 DATA_TYPE = ASCII_REAL FORMAT = "F5.2" DESCRIPTION = "Open Source +40V Bias Oscillator Drive Current " UNIT = "V" VALID_MINIMUM = -0.05 VALID_MAXIMUM = 5.1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 68 NAME = "d1Bias70" BYTES = 5 DATA_TYPE = ASCII_REAL FORMAT = "F5.2" DESCRIPTION = "Open Source primary Filament Bias Oscillator Drive Current" UNIT = "V" VALID_MINIMUM = -0.05 VALID_MAXIMUM = 5.1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 69 NAME = "d2Bias70" BYTES = 5 DATA_TYPE = ASCII_REAL FORMAT = "F5.2" DESCRIPTION = "Open Source secondary Filament Bias Oscillator Drive Current" UNIT = "V" VALID_MINIMUM = -0.05 VALID_MAXIMUM = 5.1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 70 NAME = "dGround2" BYTES = 5 DATA_TYPE = ASCII_REAL FORMAT = "F5.2" DESCRIPTION = "Ground reference voltage" UNIT = "V" VALID_MINIMUM = -0.05 VALID_MAXIMUM = 5.1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 71 NAME = "dAmString" BYTES = 9 DATA_TYPE = ASCII_REAL FORMAT = "F9.4" DESCRIPTION = "AM Board Resistor Divider String Current" UNIT = "V" VALID_MINIMUM = -645. VALID_MAXIMUM = 5.1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 72 NAME = "dFbString" BYTES = 9 DATA_TYPE = ASCII_REAL FORMAT = "F9.4" DESCRIPTION = "FB Board Resistor Divider String Current" UNIT = "V" VALID_MINIMUM = -513. VALID_MAXIMUM = 4.1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 73 NAME = "dBaCollector" BYTES = 5 DATA_TYPE = ASCII_REAL FORMAT = "F5.2" DESCRIPTION = "BA pressure gage collector current" UNIT = "V" VALID_MINIMUM = -0.05 VALID_MAXIMUM = 5.1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 74 NAME = "dFbControl" BYTES = 5 DATA_TYPE = ASCII_REAL FORMAT = "F5.2" DESCRIPTION = "-390V Regulator Control Voltage " UNIT = "V" VALID_MINIMUM = -0.05 VALID_MAXIMUM = 5.1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 75 NAME = "d3Emission" BYTES = 8 DATA_TYPE = ASCII_REAL FORMAT = "F8.5" DESCRIPTION = "Emission Current of primary closed source filament" UNIT = "uA" VALID_MINIMUM = -0.5 VALID_MAXIMUM = 25.75 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 76 NAME = "d4Emission" BYTES = 8 DATA_TYPE = ASCII_REAL FORMAT = "F8.5" DESCRIPTION = "Emission Current of secondary closed source filament" UNIT = "uA" VALID_MINIMUM = -0.5 VALID_MAXIMUM = 25.75 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 77 NAME = "dImon2" BYTES = 8 DATA_TYPE = ASCII_REAL FORMAT = "F8.6" DESCRIPTION = "Input current" UNIT = "A" VALID_MINIMUM = 0.0 VALID_MAXIMUM = 1.75 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 78 NAME = "dEb4_4" BYTES = 5 DATA_TYPE = ASCII_REAL FORMAT = "F5.2" DESCRIPTION = "anode 3 current monitor in volts" UNIT = "V" VALID_MINIMUM = -0.05 VALID_MAXIMUM = 5.1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 79 NAME = "d3Current" BYTES = 8 DATA_TYPE = ASCII_REAL FORMAT = "F8.5" DESCRIPTION = "Primary closed source filament current" UNIT = "A" VALID_MINIMUM = -0.5 VALID_MAXIMUM = 1.5 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 80 NAME = "d4Current" BYTES = 8 DATA_TYPE = ASCII_REAL FORMAT = "F8.5" DESCRIPTION = "Secondary closed source filament current" UNIT = "A" VALID_MINIMUM = -0.5 VALID_MAXIMUM = 1.5 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 81 NAME = "d4Anode" BYTES = 8 DATA_TYPE = ASCII_REAL FORMAT = "F8.5" DESCRIPTION = "Primary closed source anode current" UNIT = "uA" VALID_MINIMUM = -0.1 VALID_MAXIMUM = 10.2 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 82 NAME = "d3Anode" BYTES = 8 DATA_TYPE = ASCII_REAL FORMAT = "F8.5" DESCRIPTION = "Secondary closed source anode current" UNIT = "uA" VALID_MINIMUM = -0.1 VALID_MAXIMUM = 10.2 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 83 NAME = "d3Bias50" BYTES = 5 DATA_TYPE = ASCII_REAL FORMAT = "F5.2" DESCRIPTION = "Closed Source +40V Bias Oscillator Drive Current" UNIT = "V" VALID_MINIMUM = -0.05 VALID_MAXIMUM = 5.1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 84 NAME = "d3Bias70" BYTES = 5 DATA_TYPE = ASCII_REAL FORMAT = "F5.2" DESCRIPTION = "Closed Source primary Filament Bias Oscillator Drive Current" UNIT = "V" VALID_MINIMUM = -0.05 VALID_MAXIMUM = 5.1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 85 NAME = "d4Bias70" BYTES = 5 DATA_TYPE = ASCII_REAL FORMAT = "F5.2" DESCRIPTION = "Closed Source secondary Filament Bias Oscillator Drive Current" UNIT = "V" VALID_MINIMUM = -0.05 VALID_MAXIMUM = 5.1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 86 NAME = "dRfSupplyTemp" BYTES = 9 DATA_TYPE = ASCII_REAL FORMAT = "F9.6" DESCRIPTION = "RF power supply temperature" UNIT = "C" VALID_MINIMUM = 13. VALID_MAXIMUM = 32.5 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 87 NAME = "dFbSupplyTemp" BYTES = 9 DATA_TYPE = ASCII_REAL FORMAT = "F9.6" DESCRIPTION = "FB Board temperature" UNIT = "C" VALID_MINIMUM = 13. VALID_MAXIMUM = 32.5 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 88 NAME = "dEmSupplyTemp" BYTES = 9 DATA_TYPE = ASCII_REAL FORMAT = "F9.6" DESCRIPTION = "EM Board temperature" UNIT = "C" VALID_MINIMUM = 13. VALID_MAXIMUM = 32.5 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 89 NAME = "dPlus5Fb" BYTES = 5 DATA_TYPE = ASCII_REAL FORMAT = "F5.2" DESCRIPTION = "Thermister +5 reference voltage" UNIT = "V" VALID_MINIMUM = -0.05 VALID_MAXIMUM = 5.1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 90 NAME = "dBaGrid" BYTES = 8 DATA_TYPE = ASCII_REAL FORMAT = "F8.4" DESCRIPTION = "BA pressure gage grid current" UNIT = "uA" VALID_MINIMUM = -2. VALID_MAXIMUM = 152. END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 91 NAME = "dOl1" BYTES = 8 DATA_TYPE = ASCII_REAL FORMAT = "F8.5" DESCRIPTION = "Open Lens 1 (CEU) Current" UNIT = "uA" VALID_MINIMUM = -0.1 VALID_MAXIMUM = 6.8 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 92 NAME = "dOl2" BYTES = 8 DATA_TYPE = ASCII_REAL FORMAT = "F8.5" DESCRIPTION = "Open Lens 2 (CEU) Current " UNIT = "uA" VALID_MINIMUM = -0.1 VALID_MAXIMUM = 6.8 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 93 NAME = "dBaCurrent" BYTES = 9 DATA_TYPE = ASCII_REAL FORMAT = "F9.6" DESCRIPTION = "BA pressure gage filament current" UNIT = "A RMS" VALID_MINIMUM = -0.05 VALID_MAXIMUM = 1.4 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 94 NAME = "dBaEmission" BYTES = 8 DATA_TYPE = ASCII_REAL FORMAT = "F8.4" DESCRIPTION = "BA pressure gage emission current" UNIT = "uA" VALID_MINIMUM = -1.6 VALID_MAXIMUM = 193.75 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 95 NAME = "dGround3" BYTES = 5 DATA_TYPE = ASCII_REAL FORMAT = "F5.2" DESCRIPTION = "Ground reference voltage" UNIT = "V" VALID_MINIMUM = -0.5 VALID_MAXIMUM = 5.1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 96 NAME = "dBaBias" BYTES = 5 DATA_TYPE = ASCII_REAL FORMAT = "F5.2" DESCRIPTION = "BA pressure gage bias oscillator drive current" UNIT = "V" VALID_MINIMUM = -0.5 VALID_MAXIMUM = 5.1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 97 NAME = "dRfAgc" BYTES = 5 DATA_TYPE = ASCII_REAL FORMAT = "F5.2" DESCRIPTION = "RF automatic gain control monitor voltage" UNIT = "V" VALID_MINIMUM = -0.5 VALID_MAXIMUM = 5.1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 98 NAME = "dMinus5_7" BYTES = 7 DATA_TYPE = ASCII_REAL FORMAT = "F7.4" DESCRIPTION = "Monitor -5.7 Volt supply" UNIT = "V" VALID_MINIMUM = -7. VALID_MAXIMUM = 5.2 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 99 NAME = "dFcTemp" BYTES = 9 DATA_TYPE = ASCII_REAL FORMAT = "F9.6" DESCRIPTION = "Flight computer board temperature" UNIT = "C" VALID_MINIMUM = 18.5 VALID_MAXIMUM = 36.75 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 100 NAME = "dLvpStemp" BYTES = 9 DATA_TYPE = ASCII_REAL FORMAT = "F9.6" DESCRIPTION = "Low voltage power supply frame temperature" UNIT = "C" VALID_MINIMUM = 23.25 VALID_MAXIMUM = 31.25 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 101 NAME = "dEm1Current" BYTES = 7 DATA_TYPE = ASCII_REAL FORMAT = "F7.4" DESCRIPTION = "Electron multiplier 1 current monitor" UNIT = "KV" VALID_MINIMUM = -0.5 VALID_MAXIMUM = 38.1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 102 NAME = "dEm2Current" BYTES = 7 DATA_TYPE = ASCII_REAL FORMAT = "F7.4" DESCRIPTION = "Electron multiplier 2 current monitor" UNIT = "KV" VALID_MINIMUM = -0.5 VALID_MAXIMUM = 38.1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 103 NAME = "dImon3" BYTES = 8 DATA_TYPE = ASCII_REAL FORMAT = "F8.6" DESCRIPTION = "Input current" UNIT = "A" VALID_MINIMUM = 0.0 VALID_MAXIMUM = 1.75 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 104 NAME = "dMultAna1" BYTES = 5 DATA_TYPE = ASCII_REAL FORMAT = "F5.2" DESCRIPTION = "Pulse Amp 1 Analog Voltage Proportional to Input Frequency " UNIT = "uA" VALID_MINIMUM = -0.1 VALID_MAXIMUM = 10.2 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 105 NAME = "dMultAna2" BYTES = 6 DATA_TYPE = ASCII_REAL FORMAT = "F6.3" DESCRIPTION = "Pulse Amp 2 Analog Voltage Proportional to Input Frequency " UNIT = "uA" VALID_MINIMUM = -0.05 VALID_MAXIMUM = 1.75 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 106 NAME = "dPlus5r" BYTES = 5 DATA_TYPE = ASCII_REAL FORMAT = "F5.2" DESCRIPTION = "Monitor 5R voltage" UNIT = "V" VALID_MINIMUM = -0.1 VALID_MAXIMUM = 10.2 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 107 NAME = "dThermPressInt" BYTES = 5 DATA_TYPE = ASCII_REAL FORMAT = "F5.2" DESCRIPTION = "Internal BA pressure gage temperature" UNIT = "V" VALID_MINIMUM = -0.05 VALID_MAXIMUM = 5.1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 108 NAME = "dThermPressExt" BYTES = 5 DATA_TYPE = ASCII_REAL FORMAT = "F5.2" DESCRIPTION = "External BA pressure gage temperature" UNIT = "V" VALID_MINIMUM = -0.05 VALID_MAXIMUM = 5.1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 109 NAME = "dPlus13" BYTES = 7 DATA_TYPE = ASCII_REAL FORMAT = "F7.4" DESCRIPTION = "Monitor +13 voltage" UNIT = "V" VALID_MINIMUM = -0.2 VALID_MAXIMUM = 14.75 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 110 NAME = "nIndex" BYTES = 3 DATA_TYPE = ASCII_INTEGER FORMAT = "I3" DESCRIPTION = "AMUX index of first channel sampled for latest scan." VALID_MINIMUM = 0 VALID_MAXIMUM = 255 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 111 NAME = "dRfFreq" BYTES = 5 DATA_TYPE = ASCII_REAL FORMAT = "F5.3" DESCRIPTION = "Frequency monitor" VALID_MINIMUM = 0.0 VALID_MAXIMUM = 0.22 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 112 NAME = "nCpuIdleCounter" BYTES = 2 DATA_TYPE = ASCII_INTEGER FORMAT = "I2" DESCRIPTION = "Flight computer heartbeat counter" VALID_MINIMUM = 0 VALID_MAXIMUM = 15 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 113 NAME = "bDisc0Reset" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Set to 1 on bootup to indicate last CPU reset was due to BIU discrete 0." VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 114 NAME = "bAllSysGo" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Master INMS error flag" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 115 NAME = "bAllSysGoLatched" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Latched version of master INMS error flag" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 116 NAME = "bExcNoHandler" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "unhandled exception occured " VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 117 NAME = "bSafeMode" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "not used" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 118 NAME = "bForcedSleep" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Indicates the instrument entered Sleep state due to detected high value on IMONs" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 119 NAME = "bBiuAutoInit" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "3-bit field that counts BIU auto-initializations." END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 120 NAME = "bGseTest" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "not used" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 121 NAME = "bSystemInitialized" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Indicates system initialization complete" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 122 NAME = "bSystemConfigured" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Indicates system configuration is complete" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 123 NAME = "bTgoDetect" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Readout of watchdog reset latch on FC board during bootup. Usually set to 1 - unreliable indicator." VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 124 NAME = "bBiuReseToCc" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Indicates that a BIU reset has occured" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 125 NAME = "bIcError" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Set to 1 on bootup if reset is due to wayward instruction counter (jump to location 0)." VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 126 NAME = "bTgoToggle" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Toggled between 1 and 0 each time the Watchdog Reset Task executes" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 127 NAME = "nSubModuleID" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I2" DESCRIPTION = "Ada exception sub-module ID (CSU) 0=SciPkt, 1= Usid, 4=UseqISR, 8=USIDLostSync" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 128 NAME = "nTrapFlag" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Ada exception/error type: 0=Trace_Trap, 1=Error_Trap, 2=Exception_Trap" VALID_MINIMUM = 0 VALID_MAXIMUM = 3 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 129 NAME = "nModuleId" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I2" DESCRIPTION = "Ada exception module ID (CSC) 1=INMS_Exec, 2=INMS_Init, 3=AMux_IO, 4=DMux_IO, 5=DCon_IO, 6=CDS_IO, 7=Useq_IO, 8-10=spare, 11=Filament Control, 12=Ion Source Select Control, 13=Ion Focus Control, 14=HV Focus Control, 15=Quad Rod Control, 16=Ion Det. Control, 17=Ion Pump Control, 18=Pressure Sensor Monitor, 19=Power Supply Monitor, 20=Micro-Sequencer Control" VALID_MINIMUM = 0 VALID_MAXIMUM = 63 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 130 NAME = "bInmsBitFail" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Bootstrap Built-in-Test results" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 131 NAME = "bTmBuffOvrflw" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Set when the allotted memory buffer area for TM packets would have overflowed" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 132 NAME = "bAlfBoot" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Set when an ALF Boot is performed" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 133 NAME = "bAlfError" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Set when any BIU or ALF error is detected during an ALF Boot" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 134 NAME = "bBiuMemerror" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Set when background BIU verification processing detects a bad BIU memory location. No longer used." VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 135 NAME = "bOdbfrOverflow" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Output data buffer overflow. Not used" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 136 NAME = "bUseqOOffline" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Set when micro-sequencer output communication goes offline" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 137 NAME = "bUseqIOffline" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Set when micro-sequencer input communication goes offline" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 138 NAME = "bUseqError" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Set when any micro-sequencer error is detected" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 139 NAME = "b1750me" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Set when the 1750 Machine Error interrupt occurs and FT register ❮❯ 0400h" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 140 NAME = "bAmuxError" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "not used" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 141 NAME = "bCdsOOffline" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Set when BIU/CDS output communication goes offline" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 142 NAME = "bCdsIOffline" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Set when BIU/CDS input communication goes offline" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 143 NAME = "bCdsError" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "set if one or more of 1750ME, CDSoOffline or CDSiOffline are set" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 144 NAME = "bRteError" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = "Set any time bootstrap or RTE processing detects any of the following errors: 1750 BIT Fail; Any Memory Test fails; Unhandled Exceptions; Machine Error; TGO Reset or Wayward IC Reboot" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 145 NAME = "nMemChecksum" BYTES = 1 DATA_TYPE = ASCII_INTEGER FORMAT = "I1" DESCRIPTION = " memory checksum error flag in FSW Version 8 or later 0(ok) 1(bad checksum)" VALID_MINIMUM = 0 VALID_MAXIMUM = 1 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 146 NAME = "nStmCounter" BYTES = 3 DATA_TYPE = ASCII_INTEGER FORMAT = "I3" DESCRIPTION = "Count of spacecraft tm mode message received (1 per second)" VALID_MINIMUM = 0 VALID_MAXIMUM = 255 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 147 NAME = "nRtiCounter" BYTES = 3 DATA_TYPE = ASCII_INTEGER FORMAT = "I3" DESCRIPTION = "Count of RTIs processed" VALID_MINIMUM = 0 VALID_MAXIMUM = 255 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 148 NAME = "nMassTable" BYTES = 3 DATA_TYPE = ASCII_INTEGER FORMAT = "I3" DESCRIPTION = "value of initial mass in current mass table" VALID_MINIMUM = 0 VALID_MAXIMUM = 255 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 149 NAME = "nCmdSerno1" BYTES = 3 DATA_TYPE = ASCII_INTEGER FORMAT = "I3" DESCRIPTION = "Serial Number and Time of the telecommand that is being acknowledged. Only two are maintained for each Packet" VALID_MINIMUM = 0 VALID_MAXIMUM = 255 END_OBJECT = FIELD OBJECT = FIELD FIELD_NUMBER = 150 NAME = "nSclkMilliSec" BYTES = 9 DATA_TYPE = ASCII_INTEGER FORMAT = "I9" DESCRIPTION = "The milliseconds of the time of the packet. When used in combination with TSCLKTIME produces the exact spacecraft clock time the packet was generated" END_OBJECT = FIELD |