/* 14-Sep-2004 D. Gell Updates Per J. Mafi */
/* Added FIELD_NUMBER keyword */
/* */
/*******************************************************************/
OBJECT = FIELD
FIELD_NUMBER = 1
NAME = "nOriginalPacketID"
BYTES = 10
DATA_TYPE = ASCII_INTEGER
FORMAT = "I10"
DESCRIPTION = "The unique database ID of the packet"
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 2
NAME = "nEventID"
BYTES = 10
DATA_TYPE = ASCII_INTEGER
FORMAT = "I10"
DESCRIPTION = "The ID that references the INMSDB data
event the telemetry packet belongs to"
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 3
NAME = "nAssocSciOrigpacketID"
BYTES = 10
DATA_TYPE = ASCII_INTEGER
FORMAT = "I10"
DESCRIPTION = "The associated science packet (the nearest
science packet chronologically) for this HK
packet. ** Not currently used."
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 4
NAME = "tSclkTime"
BYTES = 23
DATA_TYPE = CHARACTER
FORMAT = "A23"
DESCRIPTION = "The spacecraft clock time of the packet -
does not include milliseconds (see
NSCLKMillis below for milliseconds)"
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 5
NAME = "dSclkRaw"
BYTES = 15
DATA_TYPE = ASCII_REAL
FORMAT = "F15.1"
DESCRIPTION = "The raw spacecraft clock time that
TSCLKTIME and NSCLKMillis were generated
from"
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 6
NAME = "tErtTime"
BYTES = 23
DATA_TYPE = CHARACTER
FORMAT = "A23"
DESCRIPTION = "The Earth Receive Time - the time the
packet was received from a NASA DSN
station"
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 7
NAME = "tProcessedTime"
BYTES = 23
DATA_TYPE = CHARACTER
FORMAT = "A23"
DESCRIPTION = "The UTC time the packet was processed by
the INMS data system"
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 8
NAME = "sMode"
BYTES = 10
DATA_TYPE = CHARACTER
FORMAT = "A10"
DESCRIPTION = "Packet mode, indicates if the packet is
data or synthetic test data"
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 9
NAME = "bValid"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Indicates that the packet is a valid
packet"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 10
NAME = "nInstMode"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Specifies the instrument operating mode, "
VALID_MINIMUM = 0
VALID_MAXIMUM = 7
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 11
NAME = "nSequenceTable"
BYTES = 2
DATA_TYPE = ASCII_INTEGER
FORMAT = "I2"
DESCRIPTION = "Sequence table number"
VALID_MINIMUM = 0
VALID_MAXIMUM = 31
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 12
NAME = "nCycleIndex"
BYTES = 2
DATA_TYPE = ASCII_INTEGER
FORMAT = "I2"
DESCRIPTION = "Index of the cycle table entry"
VALID_MINIMUM = 0
VALID_MAXIMUM = 15
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 13
NAME = "nScanIndex"
BYTES = 2
DATA_TYPE = ASCII_INTEGER
FORMAT = "I2"
DESCRIPTION = "The number of the scan within the cycle"
VALID_MINIMUM = 0
VALID_MAXIMUM = 15
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 14
NAME = "nElapsedTime"
BYTES = 5
DATA_TYPE = ASCII_INTEGER
FORMAT = "I5"
DESCRIPTION = "The time elapsed since the start of the
current sequence table"
UNIT = "s"
VALID_MINIMUM = 0
VALID_MAXIMUM = 65535
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 15
NAME = "nCycleTable"
BYTES = 2
DATA_TYPE = ASCII_INTEGER
FORMAT = "I2"
DESCRIPTION = "Cycle table number"
VALID_MINIMUM = 0
VALID_MAXIMUM = 63
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 16
NAME = "nspare1"
BYTES = 17
DATA_TYPE = ASCII_INTEGER
FORMAT = "I2"
DESCRIPTION = "2-bit field. LSB=ScanIndex MSB, MSB=CycleIndex MSB"
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 17
NAME = "nDataSumN"
BYTES = 3
DATA_TYPE = ASCII_INTEGER
FORMAT = "I3"
DESCRIPTION = "Number of mass scans being co-added to reduce
telemetry requirements"
VALID_MINIMUM = 0
VALID_MAXIMUM = 255
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 18
NAME = "nThermStatus"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Thermistor test status. Performed before pressure BA
test. Only valid prior to cover removal."
VALID_MINIMUM = 0
VALID_MAXIMUM = 3
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 19
NAME = "nThermDelta"
BYTES = 4
DATA_TYPE = ASCII_INTEGER
FORMAT = "I4"
DESCRIPTION = "Thermistor pressure AMUX value. Amux ID=49.
Valid only prior to cover removal."
VALID_MINIMUM = -512
VALID_MAXIMUM = 512
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 20
NAME = "nFswVersion"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I3"
DESCRIPTION = "Reports the flight software version"
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 21
NAME = "nBaStatus"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Pressure test status, valid only prior to cover removal"
VALID_MINIMUM = 0
VALID_MAXIMUM = 3
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 22
NAME = "nBaStep"
BYTES = 2
DATA_TYPE = ASCII_INTEGER
FORMAT = "I2"
DESCRIPTION = "BA DAC emission value. Valid only prior to cover removal."
VALID_MINIMUM = 0
VALID_MAXIMUM = 15
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 23
NAME = "nBaValue"
BYTES = 2
DATA_TYPE = ASCII_INTEGER
FORMAT = "I2"
DESCRIPTION = "Pressure at end of test. Valid only prior to cover removal"
VALID_MINIMUM = 0
VALID_MAXIMUM = 15
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 24
NAME = "nTcReceived"
BYTES = 3
DATA_TYPE = ASCII_INTEGER
FORMAT = "I3"
DESCRIPTION = "Number of telecommands received"
VALID_MINIMUM = 0
VALID_MAXIMUM = 255
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 25
NAME = "nAlfReceived"
BYTES = 3
DATA_TYPE = ASCII_INTEGER
FORMAT = "I3"
DESCRIPTION = "Indicates a BIU bus error"
VALID_MINIMUM = 0
VALID_MAXIMUM = 255
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 26
NAME = "nAlfRejected"
BYTES = 2
DATA_TYPE = ASCII_INTEGER
FORMAT = "I2"
DESCRIPTION = "Indicates a 1750 machine error"
VALID_MINIMUM = 0
VALID_MAXIMUM = 15
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 27
NAME = "nTcRejected"
BYTES = 2
DATA_TYPE = ASCII_INTEGER
FORMAT = "I2"
DESCRIPTION = "Number of telecommads rejected"
VALID_MINIMUM = 0
VALID_MAXIMUM = 15
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 28
NAME = "nInstTmMode"
BYTES = 3
DATA_TYPE = ASCII_INTEGER
FORMAT = "I3"
DESCRIPTION = "Telmetry mode index"
VALID_MINIMUM = 0
VALID_MAXIMUM = 255
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 29
NAME = "nBiuSpare1"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Readback of BIU discretes 6 and 7"
VALID_MINIMUM = 0
VALID_MAXIMUM = 3
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 30
NAME = "bTgordt"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Readback of Flight computer boot mode descrete"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 31
NAME = "bAlfOverInhibit"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Readback of ALF override inhibit discrete"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 32
NAME = "bAlfBootEnable"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Readback of ALF boot enable discrete"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 33
NAME = "bDefSciEnable"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Readback of default science enable descrete"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 34
NAME = "bBiuSleep"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "readback of sleep discrete"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 35
NAME = "bBiuPord0"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "readback of BIU discrete 0"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 36
NAME = "bHkFull"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "BIU error flag set when houskeeping tm buffer is full"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 37
NAME = "bHkSsysf"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "BIU error flag set when subsystem fail bit is set
in 1553 status word"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 38
NAME = "bHkMsgError"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "BIU error flag set when message error bit is set
in 1553 status word"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 39
NAME = "bTmScError"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "BIU error flag set when the number words expected
in 1553 receive sub-address 29 is incorrect"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 40
NAME = "bStTblError"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "BIU error flag set when the number words expected in
1553 receive sub-address 19 is incorrect"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 41
NAME = "bAncbcError"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "BIU error flag set when the number words expected in
1553 receive sub-address 10 is incorrect"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 42
NAME = "bbiuspare2"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "spare, always 0"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 43
NAME = "bRtiSfail"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Set when no RTIs have been received for 2 seconds"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 44
NAME = "bFil1On"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "State of primary open source filament"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 45
NAME = "bFil2On"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "State of secondary open source filament"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 46
NAME = "bFil3On"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "State of primary closed source filament"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 47
NAME = "bFil4On"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "State of secondary closed source filament"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 48
NAME = "bDconSpare1"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "spare"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 49
NAME = "bFil6On"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "State of BA pressure gauge filament"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 50
NAME = "nDconSpare2"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "spare"
VALID_MINIMUM = 0
VALID_MAXIMUM = 3
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 51
NAME = "bBiuWdx"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "BIU watchdog timer status, 1(ok) 0(expired)"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 52
NAME = "bBiuFt"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "BIU write status, set to 0 when a BIU bus timeout
is detected in boot code"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 53
NAME = "bFcft"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "BIU write status, set to 0 when a CPU Machine Error
is detected in boot code"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 54
NAME = "bFctGo"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "BIU write status, set when TGO reset indicator latch
is set on bootup. Always set to 0 in TM."
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 55
NAME = "bFcillad"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "BIU write status, set to 0 when CPU accesses an
illegal address. Always set to 0 in TM."
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 56
NAME = "bFcnpu"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "BIU write status, set to 1 when CPU completes a
normal power up. Always set to 0 in TM."
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 57
NAME = "bFcsuren"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "BIU write status, set to 0 when CPU start-up RAM
is enabled. Always set to 0 in TM."
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 58
NAME = "bBiuDtsLoaded"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "BIU write status, set to 1 when BIU descriptor table
is loaded on bootup."
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 59
NAME = "d1emission"
BYTES = 7
DATA_TYPE = ASCII_REAL
FORMAT = "F7.4"
DESCRIPTION = "Emission Current of primary open source filament"
UNIT = "uA"
VALID_MINIMUM = -0.5
VALID_MAXIMUM = 25.75
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 60
NAME = "d2emission"
BYTES = 8
DATA_TYPE = ASCII_REAL
FORMAT = "F8.5"
DESCRIPTION = "Emission Current of secondary open source filament"
UNIT = "uA"
VALID_MINIMUM = 0.05
VALID_MAXIMUM = 25.75
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 61
NAME = "dImon1"
BYTES = 8
DATA_TYPE = ASCII_REAL
FORMAT = "F8.6"
DESCRIPTION = "Input current"
UNIT = "A"
VALID_MINIMUM = 0.0
VALID_MAXIMUM = 1.75
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 62
NAME = "dGround1"
BYTES = 5
DATA_TYPE = ASCII_REAL
FORMAT = "F5.2"
DESCRIPTION = "Ground reference voltage"
UNIT = "V"
VALID_MINIMUM = -0.05
VALID_MAXIMUM = 5.1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 63
NAME = "d1Current"
BYTES = 8
DATA_TYPE = ASCII_REAL
FORMAT = "F8.5"
DESCRIPTION = "Primary open source filament current"
UNIT = "A"
VALID_MINIMUM = -0.1
VALID_MAXIMUM = 1.5
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 64
NAME = "d2Current"
BYTES = 8
DATA_TYPE = ASCII_REAL
FORMAT = "F8.5"
DESCRIPTION = "Secondary open source filament current"
UNIT = "A"
VALID_MINIMUM = -0.1
VALID_MAXIMUM = 1.5
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 65
NAME = "d1Target"
BYTES = 8
DATA_TYPE = ASCII_REAL
FORMAT = "F8.5"
DESCRIPTION = "Primary open source anode current"
UNIT = "uA"
VALID_MINIMUM = -0.5
VALID_MAXIMUM = 27.75
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 66
NAME = "d2Target"
BYTES = 8
DATA_TYPE = ASCII_REAL
FORMAT = "F8.5"
DESCRIPTION = "Secondary open source anode current"
UNIT = "uA"
VALID_MINIMUM = -0.5
VALID_MAXIMUM = 27.75
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 67
NAME = "d1Bias50"
BYTES = 5
DATA_TYPE = ASCII_REAL
FORMAT = "F5.2"
DESCRIPTION = "Open Source +40V Bias Oscillator Drive
Current "
UNIT = "V"
VALID_MINIMUM = -0.05
VALID_MAXIMUM = 5.1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 68
NAME = "d1Bias70"
BYTES = 5
DATA_TYPE = ASCII_REAL
FORMAT = "F5.2"
DESCRIPTION = "Open Source primary Filament Bias Oscillator Drive Current"
UNIT = "V"
VALID_MINIMUM = -0.05
VALID_MAXIMUM = 5.1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 69
NAME = "d2Bias70"
BYTES = 5
DATA_TYPE = ASCII_REAL
FORMAT = "F5.2"
DESCRIPTION = "Open Source secondary Filament Bias
Oscillator Drive Current"
UNIT = "V"
VALID_MINIMUM = -0.05
VALID_MAXIMUM = 5.1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 70
NAME = "dGround2"
BYTES = 5
DATA_TYPE = ASCII_REAL
FORMAT = "F5.2"
DESCRIPTION = "Ground reference voltage"
UNIT = "V"
VALID_MINIMUM = -0.05
VALID_MAXIMUM = 5.1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 71
NAME = "dAmString"
BYTES = 9
DATA_TYPE = ASCII_REAL
FORMAT = "F9.4"
DESCRIPTION = "AM Board Resistor Divider String Current"
UNIT = "V"
VALID_MINIMUM = -645.
VALID_MAXIMUM = 5.1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 72
NAME = "dFbString"
BYTES = 9
DATA_TYPE = ASCII_REAL
FORMAT = "F9.4"
DESCRIPTION = "FB Board Resistor Divider String Current"
UNIT = "V"
VALID_MINIMUM = -513.
VALID_MAXIMUM = 4.1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 73
NAME = "dBaCollector"
BYTES = 5
DATA_TYPE = ASCII_REAL
FORMAT = "F5.2"
DESCRIPTION = "BA pressure gage collector current"
UNIT = "V"
VALID_MINIMUM = -0.05
VALID_MAXIMUM = 5.1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 74
NAME = "dFbControl"
BYTES = 5
DATA_TYPE = ASCII_REAL
FORMAT = "F5.2"
DESCRIPTION = "-390V Regulator Control Voltage "
UNIT = "V"
VALID_MINIMUM = -0.05
VALID_MAXIMUM = 5.1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 75
NAME = "d3Emission"
BYTES = 8
DATA_TYPE = ASCII_REAL
FORMAT = "F8.5"
DESCRIPTION = "Emission Current of primary closed source filament"
UNIT = "uA"
VALID_MINIMUM = -0.5
VALID_MAXIMUM = 25.75
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 76
NAME = "d4Emission"
BYTES = 8
DATA_TYPE = ASCII_REAL
FORMAT = "F8.5"
DESCRIPTION = "Emission Current of secondary closed source filament"
UNIT = "uA"
VALID_MINIMUM = -0.5
VALID_MAXIMUM = 25.75
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 77
NAME = "dImon2"
BYTES = 8
DATA_TYPE = ASCII_REAL
FORMAT = "F8.6"
DESCRIPTION = "Input current"
UNIT = "A"
VALID_MINIMUM = 0.0
VALID_MAXIMUM = 1.75
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 78
NAME = "dEb4_4"
BYTES = 5
DATA_TYPE = ASCII_REAL
FORMAT = "F5.2"
DESCRIPTION = "anode 3 current monitor in volts"
UNIT = "V"
VALID_MINIMUM = -0.05
VALID_MAXIMUM = 5.1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 79
NAME = "d3Current"
BYTES = 8
DATA_TYPE = ASCII_REAL
FORMAT = "F8.5"
DESCRIPTION = "Primary closed source filament current"
UNIT = "A"
VALID_MINIMUM = -0.5
VALID_MAXIMUM = 1.5
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 80
NAME = "d4Current"
BYTES = 8
DATA_TYPE = ASCII_REAL
FORMAT = "F8.5"
DESCRIPTION = "Secondary closed source filament current"
UNIT = "A"
VALID_MINIMUM = -0.5
VALID_MAXIMUM = 1.5
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 81
NAME = "d4Anode"
BYTES = 8
DATA_TYPE = ASCII_REAL
FORMAT = "F8.5"
DESCRIPTION = "Primary closed source anode current"
UNIT = "uA"
VALID_MINIMUM = -0.1
VALID_MAXIMUM = 10.2
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 82
NAME = "d3Anode"
BYTES = 8
DATA_TYPE = ASCII_REAL
FORMAT = "F8.5"
DESCRIPTION = "Secondary closed source anode current"
UNIT = "uA"
VALID_MINIMUM = -0.1
VALID_MAXIMUM = 10.2
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 83
NAME = "d3Bias50"
BYTES = 5
DATA_TYPE = ASCII_REAL
FORMAT = "F5.2"
DESCRIPTION = "Closed Source +40V Bias Oscillator Drive Current"
UNIT = "V"
VALID_MINIMUM = -0.05
VALID_MAXIMUM = 5.1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 84
NAME = "d3Bias70"
BYTES = 5
DATA_TYPE = ASCII_REAL
FORMAT = "F5.2"
DESCRIPTION = "Closed Source primary Filament Bias Oscillator
Drive Current"
UNIT = "V"
VALID_MINIMUM = -0.05
VALID_MAXIMUM = 5.1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 85
NAME = "d4Bias70"
BYTES = 5
DATA_TYPE = ASCII_REAL
FORMAT = "F5.2"
DESCRIPTION = "Closed Source secondary Filament Bias Oscillator
Drive Current"
UNIT = "V"
VALID_MINIMUM = -0.05
VALID_MAXIMUM = 5.1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 86
NAME = "dRfSupplyTemp"
BYTES = 9
DATA_TYPE = ASCII_REAL
FORMAT = "F9.6"
DESCRIPTION = "RF power supply temperature"
UNIT = "C"
VALID_MINIMUM = 13.
VALID_MAXIMUM = 32.5
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 87
NAME = "dFbSupplyTemp"
BYTES = 9
DATA_TYPE = ASCII_REAL
FORMAT = "F9.6"
DESCRIPTION = "FB Board temperature"
UNIT = "C"
VALID_MINIMUM = 13.
VALID_MAXIMUM = 32.5
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 88
NAME = "dEmSupplyTemp"
BYTES = 9
DATA_TYPE = ASCII_REAL
FORMAT = "F9.6"
DESCRIPTION = "EM Board temperature"
UNIT = "C"
VALID_MINIMUM = 13.
VALID_MAXIMUM = 32.5
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 89
NAME = "dPlus5Fb"
BYTES = 5
DATA_TYPE = ASCII_REAL
FORMAT = "F5.2"
DESCRIPTION = "Thermister +5 reference voltage"
UNIT = "V"
VALID_MINIMUM = -0.05
VALID_MAXIMUM = 5.1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 90
NAME = "dBaGrid"
BYTES = 8
DATA_TYPE = ASCII_REAL
FORMAT = "F8.4"
DESCRIPTION = "BA pressure gage grid current"
UNIT = "uA"
VALID_MINIMUM = -2.
VALID_MAXIMUM = 152.
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 91
NAME = "dOl1"
BYTES = 8
DATA_TYPE = ASCII_REAL
FORMAT = "F8.5"
DESCRIPTION = "Open Lens 1 (CEU) Current"
UNIT = "uA"
VALID_MINIMUM = -0.1
VALID_MAXIMUM = 6.8
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 92
NAME = "dOl2"
BYTES = 8
DATA_TYPE = ASCII_REAL
FORMAT = "F8.5"
DESCRIPTION = "Open Lens 2 (CEU) Current "
UNIT = "uA"
VALID_MINIMUM = -0.1
VALID_MAXIMUM = 6.8
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 93
NAME = "dBaCurrent"
BYTES = 9
DATA_TYPE = ASCII_REAL
FORMAT = "F9.6"
DESCRIPTION = "BA pressure gage filament current"
UNIT = "A RMS"
VALID_MINIMUM = -0.05
VALID_MAXIMUM = 1.4
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 94
NAME = "dBaEmission"
BYTES = 8
DATA_TYPE = ASCII_REAL
FORMAT = "F8.4"
DESCRIPTION = "BA pressure gage emission current"
UNIT = "uA"
VALID_MINIMUM = -1.6
VALID_MAXIMUM = 193.75
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 95
NAME = "dGround3"
BYTES = 5
DATA_TYPE = ASCII_REAL
FORMAT = "F5.2"
DESCRIPTION = "Ground reference voltage"
UNIT = "V"
VALID_MINIMUM = -0.5
VALID_MAXIMUM = 5.1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 96
NAME = "dBaBias"
BYTES = 5
DATA_TYPE = ASCII_REAL
FORMAT = "F5.2"
DESCRIPTION = "BA pressure gage bias oscillator drive current"
UNIT = "V"
VALID_MINIMUM = -0.5
VALID_MAXIMUM = 5.1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 97
NAME = "dRfAgc"
BYTES = 5
DATA_TYPE = ASCII_REAL
FORMAT = "F5.2"
DESCRIPTION = "RF automatic gain control monitor voltage"
UNIT = "V"
VALID_MINIMUM = -0.5
VALID_MAXIMUM = 5.1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 98
NAME = "dMinus5_7"
BYTES = 7
DATA_TYPE = ASCII_REAL
FORMAT = "F7.4"
DESCRIPTION = "Monitor -5.7 Volt supply"
UNIT = "V"
VALID_MINIMUM = -7.
VALID_MAXIMUM = 5.2
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 99
NAME = "dFcTemp"
BYTES = 9
DATA_TYPE = ASCII_REAL
FORMAT = "F9.6"
DESCRIPTION = "Flight computer board temperature"
UNIT = "C"
VALID_MINIMUM = 18.5
VALID_MAXIMUM = 36.75
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 100
NAME = "dLvpStemp"
BYTES = 9
DATA_TYPE = ASCII_REAL
FORMAT = "F9.6"
DESCRIPTION = "Low voltage power supply frame temperature"
UNIT = "C"
VALID_MINIMUM = 23.25
VALID_MAXIMUM = 31.25
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 101
NAME = "dEm1Current"
BYTES = 7
DATA_TYPE = ASCII_REAL
FORMAT = "F7.4"
DESCRIPTION = "Electron multiplier 1 current monitor"
UNIT = "KV"
VALID_MINIMUM = -0.5
VALID_MAXIMUM = 38.1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 102
NAME = "dEm2Current"
BYTES = 7
DATA_TYPE = ASCII_REAL
FORMAT = "F7.4"
DESCRIPTION = "Electron multiplier 2 current monitor"
UNIT = "KV"
VALID_MINIMUM = -0.5
VALID_MAXIMUM = 38.1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 103
NAME = "dImon3"
BYTES = 8
DATA_TYPE = ASCII_REAL
FORMAT = "F8.6"
DESCRIPTION = "Input current"
UNIT = "A"
VALID_MINIMUM = 0.0
VALID_MAXIMUM = 1.75
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 104
NAME = "dMultAna1"
BYTES = 5
DATA_TYPE = ASCII_REAL
FORMAT = "F5.2"
DESCRIPTION = "Pulse Amp 1 Analog Voltage Proportional to
Input Frequency "
UNIT = "uA"
VALID_MINIMUM = -0.1
VALID_MAXIMUM = 10.2
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 105
NAME = "dMultAna2"
BYTES = 6
DATA_TYPE = ASCII_REAL
FORMAT = "F6.3"
DESCRIPTION = "Pulse Amp 2 Analog Voltage Proportional to
Input Frequency "
UNIT = "uA"
VALID_MINIMUM = -0.05
VALID_MAXIMUM = 1.75
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 106
NAME = "dPlus5r"
BYTES = 5
DATA_TYPE = ASCII_REAL
FORMAT = "F5.2"
DESCRIPTION = "Monitor 5R voltage"
UNIT = "V"
VALID_MINIMUM = -0.1
VALID_MAXIMUM = 10.2
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 107
NAME = "dThermPressInt"
BYTES = 5
DATA_TYPE = ASCII_REAL
FORMAT = "F5.2"
DESCRIPTION = "Internal BA pressure gage temperature"
UNIT = "V"
VALID_MINIMUM = -0.05
VALID_MAXIMUM = 5.1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 108
NAME = "dThermPressExt"
BYTES = 5
DATA_TYPE = ASCII_REAL
FORMAT = "F5.2"
DESCRIPTION = "External BA pressure gage temperature"
UNIT = "V"
VALID_MINIMUM = -0.05
VALID_MAXIMUM = 5.1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 109
NAME = "dPlus13"
BYTES = 7
DATA_TYPE = ASCII_REAL
FORMAT = "F7.4"
DESCRIPTION = "Monitor +13 voltage"
UNIT = "V"
VALID_MINIMUM = -0.2
VALID_MAXIMUM = 14.75
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 110
NAME = "nIndex"
BYTES = 3
DATA_TYPE = ASCII_INTEGER
FORMAT = "I3"
DESCRIPTION = "AMUX index of first channel sampled for latest scan."
VALID_MINIMUM = 0
VALID_MAXIMUM = 255
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 111
NAME = "dRfFreq"
BYTES = 5
DATA_TYPE = ASCII_REAL
FORMAT = "F5.3"
DESCRIPTION = "Frequency monitor"
VALID_MINIMUM = 0.0
VALID_MAXIMUM = 0.22
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 112
NAME = "nCpuIdleCounter"
BYTES = 2
DATA_TYPE = ASCII_INTEGER
FORMAT = "I2"
DESCRIPTION = "Flight computer heartbeat counter"
VALID_MINIMUM = 0
VALID_MAXIMUM = 15
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 113
NAME = "bDisc0Reset"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Set to 1 on bootup to indicate last CPU reset was
due to BIU discrete 0."
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 114
NAME = "bAllSysGo"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Master INMS error flag"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 115
NAME = "bAllSysGoLatched"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Latched version of master INMS error flag"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 116
NAME = "bExcNoHandler"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "unhandled exception occured "
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 117
NAME = "bSafeMode"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "not used"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 118
NAME = "bForcedSleep"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Indicates the instrument entered Sleep state due to
detected high value on IMONs"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 119
NAME = "bBiuAutoInit"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "3-bit field that counts BIU auto-initializations."
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 120
NAME = "bGseTest"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "not used"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 121
NAME = "bSystemInitialized"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Indicates system initialization complete"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 122
NAME = "bSystemConfigured"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Indicates system configuration is complete"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 123
NAME = "bTgoDetect"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Readout of watchdog reset latch on FC board during bootup.
Usually set to 1 - unreliable indicator."
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 124
NAME = "bBiuReseToCc"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Indicates that a BIU reset has occured"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 125
NAME = "bIcError"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Set to 1 on bootup if reset is due to wayward
instruction counter (jump to location 0)."
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 126
NAME = "bTgoToggle"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Toggled between 1 and 0 each time the Watchdog Reset
Task executes"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 127
NAME = "nSubModuleID"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I2"
DESCRIPTION = "Ada exception sub-module ID (CSU)
0=SciPkt, 1= Usid, 4=UseqISR, 8=USIDLostSync"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 128
NAME = "nTrapFlag"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Ada exception/error type:
0=Trace_Trap, 1=Error_Trap, 2=Exception_Trap"
VALID_MINIMUM = 0
VALID_MAXIMUM = 3
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 129
NAME = "nModuleId"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I2"
DESCRIPTION = "Ada exception module ID (CSC)
1=INMS_Exec, 2=INMS_Init, 3=AMux_IO, 4=DMux_IO,
5=DCon_IO, 6=CDS_IO, 7=Useq_IO, 8-10=spare,
11=Filament Control, 12=Ion Source Select Control,
13=Ion Focus Control, 14=HV Focus Control,
15=Quad Rod Control, 16=Ion Det. Control,
17=Ion Pump Control, 18=Pressure Sensor Monitor,
19=Power Supply Monitor, 20=Micro-Sequencer Control"
VALID_MINIMUM = 0
VALID_MAXIMUM = 63
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 130
NAME = "bInmsBitFail"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Bootstrap Built-in-Test results"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 131
NAME = "bTmBuffOvrflw"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Set when the allotted memory buffer area for
TM packets would have overflowed"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 132
NAME = "bAlfBoot"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Set when an ALF Boot is performed"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 133
NAME = "bAlfError"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Set when any BIU or ALF error is detected
during an ALF Boot"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 134
NAME = "bBiuMemerror"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Set when background BIU verification processing
detects a bad BIU memory location. No longer used."
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 135
NAME = "bOdbfrOverflow"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Output data buffer overflow. Not used"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 136
NAME = "bUseqOOffline"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Set when micro-sequencer output communication
goes offline"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 137
NAME = "bUseqIOffline"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Set when micro-sequencer input communication
goes offline"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 138
NAME = "bUseqError"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Set when any micro-sequencer error is detected"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 139
NAME = "b1750me"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Set when the 1750 Machine Error interrupt occurs
and FT register ❮❯ 0400h"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 140
NAME = "bAmuxError"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "not used"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 141
NAME = "bCdsOOffline"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Set when BIU/CDS output communication goes offline"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 142
NAME = "bCdsIOffline"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Set when BIU/CDS input communication goes offline"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 143
NAME = "bCdsError"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "set if one or more of 1750ME, CDSoOffline or
CDSiOffline are set"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 144
NAME = "bRteError"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = "Set any time bootstrap or RTE processing
detects any of the following errors: 1750 BIT Fail;
Any Memory Test fails; Unhandled Exceptions;
Machine Error; TGO Reset or Wayward IC Reboot"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 145
NAME = "nMemChecksum"
BYTES = 1
DATA_TYPE = ASCII_INTEGER
FORMAT = "I1"
DESCRIPTION = " memory checksum error flag in FSW Version 8 or later
0(ok) 1(bad checksum)"
VALID_MINIMUM = 0
VALID_MAXIMUM = 1
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 146
NAME = "nStmCounter"
BYTES = 3
DATA_TYPE = ASCII_INTEGER
FORMAT = "I3"
DESCRIPTION = "Count of spacecraft tm mode message received
(1 per second)"
VALID_MINIMUM = 0
VALID_MAXIMUM = 255
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 147
NAME = "nRtiCounter"
BYTES = 3
DATA_TYPE = ASCII_INTEGER
FORMAT = "I3"
DESCRIPTION = "Count of RTIs processed"
VALID_MINIMUM = 0
VALID_MAXIMUM = 255
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 148
NAME = "nMassTable"
BYTES = 3
DATA_TYPE = ASCII_INTEGER
FORMAT = "I3"
DESCRIPTION = "value of initial mass in current mass table"
VALID_MINIMUM = 0
VALID_MAXIMUM = 255
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 149
NAME = "nCmdSerno1"
BYTES = 3
DATA_TYPE = ASCII_INTEGER
FORMAT = "I3"
DESCRIPTION = "Serial Number and Time of the telecommand that is
being acknowledged. Only two are maintained for
each Packet"
VALID_MINIMUM = 0
VALID_MAXIMUM = 255
END_OBJECT = FIELD
OBJECT = FIELD
FIELD_NUMBER = 150
NAME = "nSclkMilliSec"
BYTES = 9
DATA_TYPE = ASCII_INTEGER
FORMAT = "I9"
DESCRIPTION = "The milliseconds of the time of the
packet. When used in combination with TSCLKTIME
produces the exact spacecraft clock time the packet
was generated"
END_OBJECT = FIELD
|