Download this file

/*                                                                 */
/* 14-Sep-2004 D. Gell Updates Per J. Mafi                         */
/*                     Added FIELD_NUMBER keyword                  */
/*                                                                 */
/*******************************************************************/

OBJECT        = FIELD
  FIELD_NUMBER  = 1
  NAME          = "nOriginalPacketID"
  BYTES         = 10
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I10"
  DESCRIPTION   = "The unique database ID of the packet"
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 2
  NAME          = "nEventID"
  BYTES         = 10
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I10"
  DESCRIPTION   = "The ID that references the INMSDB data 
                   event the telemetry packet belongs to"
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 3
  NAME          = "nAssocSciOrigpacketID"
  BYTES         = 10
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I10"
  DESCRIPTION   = "The associated science packet (the nearest 
                   science packet chronologically) for this HK 
                   packet. ** Not currently used."
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 4
  NAME          = "tSclkTime"
  BYTES         = 23
  DATA_TYPE     = CHARACTER
  FORMAT        = "A23"
  DESCRIPTION   = "The spacecraft clock time of the packet - 
                   does not include milliseconds (see 
                   NSCLKMillis below for milliseconds)"
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 5
  NAME          = "dSclkRaw"
  BYTES         = 15
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F15.1"
  DESCRIPTION   = "The raw spacecraft clock time that 
                   TSCLKTIME and NSCLKMillis were generated 
                   from"
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 6
  NAME          = "tErtTime"
  BYTES         = 23
  DATA_TYPE     = CHARACTER
  FORMAT        = "A23"
  DESCRIPTION   = "The Earth Receive Time - the time the 
                   packet was received from a NASA DSN 
                   station"
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 7
  NAME          = "tProcessedTime"
  BYTES         = 23
  DATA_TYPE     = CHARACTER
  FORMAT        = "A23"
  DESCRIPTION   = "The UTC time the packet was processed by 
                   the INMS data system"
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 8
  NAME          = "sMode"
  BYTES         = 10
  DATA_TYPE     = CHARACTER
  FORMAT        = "A10"
  DESCRIPTION   = "Packet mode, indicates if the packet is 
                  data or synthetic test data"
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 9
  NAME          = "bValid"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Indicates that the packet is  a valid 
                   packet"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 10
  NAME          = "nInstMode"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Specifies the instrument operating mode, "
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 7 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 11
  NAME          = "nSequenceTable"
  BYTES         = 2
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I2"
  DESCRIPTION   = "Sequence table number"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 31 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 12
  NAME          = "nCycleIndex"
  BYTES         = 2
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I2"
  DESCRIPTION   = "Index of the cycle table entry"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 15 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 13
  NAME          = "nScanIndex"
  BYTES         = 2
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I2"
  DESCRIPTION   = "The number of the scan within the cycle"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 15 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 14
  NAME          = "nElapsedTime"
  BYTES         = 5
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I5"
  DESCRIPTION   = "The time elapsed since the start of the 
                   current sequence table"
  UNIT          = "s"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 65535 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 15
  NAME          = "nCycleTable"
  BYTES         = 2
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I2"
  DESCRIPTION   = "Cycle table number"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 63 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 16
  NAME          = "nspare1"
  BYTES         = 17
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I2"
  DESCRIPTION   = "2-bit field.  LSB=ScanIndex MSB, MSB=CycleIndex MSB"
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 17
  NAME          = "nDataSumN"
  BYTES         = 3
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I3"
  DESCRIPTION   = "Number of mass scans being co-added to reduce 
                   telemetry requirements"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 255 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 18
  NAME          = "nThermStatus"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Thermistor test status.  Performed before pressure BA 
                    test.  Only valid prior to cover removal."
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 3 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 19
  NAME          = "nThermDelta"
  BYTES         = 4
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I4"
  DESCRIPTION   = "Thermistor pressure AMUX value.  Amux ID=49. 
                   Valid only prior to cover removal."
  VALID_MINIMUM = -512 
  VALID_MAXIMUM = 512 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 20
  NAME          = "nFswVersion"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I3"
  DESCRIPTION   = "Reports the flight software version"
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 21
  NAME          = "nBaStatus"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Pressure test status, valid only prior to cover removal"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 3 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 22
  NAME          = "nBaStep"
  BYTES         = 2
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I2"
  DESCRIPTION   = "BA DAC emission value.  Valid only prior to cover removal."
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 15 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 23
  NAME          = "nBaValue"
  BYTES         = 2
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I2"
  DESCRIPTION   = "Pressure at end of test. Valid only prior to cover removal"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 15 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 24
  NAME          = "nTcReceived"
  BYTES         = 3
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I3"
  DESCRIPTION   = "Number of telecommands received"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 255 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 25
  NAME          = "nAlfReceived"
  BYTES         = 3
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I3"
  DESCRIPTION   = "Indicates a BIU bus error"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 255 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 26
  NAME          = "nAlfRejected"
  BYTES         = 2
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I2"
  DESCRIPTION   = "Indicates a 1750 machine error"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 15 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 27
  NAME          = "nTcRejected"
  BYTES         = 2
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I2"
  DESCRIPTION   = "Number of telecommads rejected"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 15 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 28
  NAME          = "nInstTmMode"
  BYTES         = 3
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I3"
  DESCRIPTION   = "Telmetry mode index"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 255 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 29
  NAME          = "nBiuSpare1"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Readback of BIU discretes 6 and 7"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 3 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 30
  NAME          = "bTgordt"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Readback of Flight computer boot mode descrete"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 31
  NAME          = "bAlfOverInhibit"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Readback of ALF override inhibit discrete"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 32
  NAME          = "bAlfBootEnable"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Readback of ALF boot enable discrete"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 33
  NAME          = "bDefSciEnable"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Readback of default science enable descrete"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 34
  NAME          = "bBiuSleep"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "readback of sleep discrete"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 35
  NAME          = "bBiuPord0"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "readback of BIU discrete 0"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 36
  NAME          = "bHkFull"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "BIU error flag set when houskeeping tm buffer is full"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 37
  NAME          = "bHkSsysf"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "BIU error flag set when subsystem fail bit is set 
                   in 1553 status word"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 38
  NAME          = "bHkMsgError"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "BIU error flag set when message error bit is set 
                   in 1553 status word"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 39
  NAME          = "bTmScError"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "BIU error flag set when the number words expected 
                   in 1553 receive sub-address 29 is incorrect"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 40
  NAME          = "bStTblError"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "BIU error flag set when the number words expected in 
                   1553 receive sub-address 19 is incorrect"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 41
  NAME          = "bAncbcError"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "BIU error flag set when the number words expected in
                   1553 receive sub-address 10 is incorrect"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 42
  NAME          = "bbiuspare2"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "spare, always 0"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 43
  NAME          = "bRtiSfail"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Set when no RTIs have been received for 2 seconds"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 44
  NAME          = "bFil1On"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "State of primary open source filament"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 45
  NAME          = "bFil2On"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "State of secondary open source filament"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 46
  NAME          = "bFil3On"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "State of primary closed source filament"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 47
  NAME          = "bFil4On"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "State of secondary closed source filament"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 48
  NAME          = "bDconSpare1"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "spare"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 49
  NAME          = "bFil6On"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "State of  BA pressure  gauge filament"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 50
  NAME          = "nDconSpare2"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "spare"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 3 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 51
  NAME          = "bBiuWdx"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "BIU watchdog timer status, 1(ok) 0(expired)"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 52
  NAME          = "bBiuFt"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "BIU write status, set to 0 when a BIU bus timeout 
                   is detected in boot code"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 53
  NAME          = "bFcft"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "BIU write status, set to 0 when a CPU Machine Error 
                   is detected in boot code"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 54
  NAME          = "bFctGo"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "BIU write status, set when TGO reset indicator latch
                   is set on bootup.  Always set to 0 in TM."
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 55
  NAME          = "bFcillad"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "BIU write status, set to 0 when CPU accesses an 
                   illegal address.  Always set to 0 in TM."
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 56
  NAME          = "bFcnpu"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "BIU write status, set to 1 when CPU completes a 
                   normal power up.  Always set to 0 in TM."
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 57
  NAME          = "bFcsuren"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "BIU write status, set to 0 when CPU start-up RAM
                   is enabled.  Always set to 0 in TM."
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 58
  NAME          = "bBiuDtsLoaded"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "BIU write status, set to 1 when BIU descriptor table
                   is loaded on bootup."
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 59
  NAME          = "d1emission"
  BYTES         = 7
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F7.4"
  DESCRIPTION   = "Emission Current of primary open source filament"
  UNIT          = "uA"
  VALID_MINIMUM = -0.5 
  VALID_MAXIMUM = 25.75
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 60
  NAME          = "d2emission"
  BYTES         = 8
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F8.5"
  DESCRIPTION   = "Emission Current of secondary open source filament"
  UNIT          = "uA"
  VALID_MINIMUM = 0.05
  VALID_MAXIMUM = 25.75
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 61
  NAME          = "dImon1"
  BYTES         = 8
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F8.6"
  DESCRIPTION   = "Input current"
  UNIT          = "A"
  VALID_MINIMUM = 0.0 
  VALID_MAXIMUM = 1.75
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 62
  NAME          = "dGround1"
  BYTES         = 5
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F5.2"
  DESCRIPTION   = "Ground reference voltage"
  UNIT          = "V"
  VALID_MINIMUM = -0.05
  VALID_MAXIMUM = 5.1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 63
  NAME          = "d1Current"
  BYTES         = 8
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F8.5"
  DESCRIPTION   = "Primary open source filament current"
  UNIT          = "A"
  VALID_MINIMUM = -0.1 
  VALID_MAXIMUM = 1.5 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 64
  NAME          = "d2Current"
  BYTES         = 8
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F8.5"
  DESCRIPTION   = "Secondary open source filament current"
  UNIT          = "A"
  VALID_MINIMUM = -0.1 
  VALID_MAXIMUM = 1.5 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 65
  NAME          = "d1Target"
  BYTES         = 8
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F8.5"
  DESCRIPTION   = "Primary open source anode current"
  UNIT          = "uA"
  VALID_MINIMUM = -0.5 
  VALID_MAXIMUM = 27.75
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 66
  NAME          = "d2Target"
  BYTES         = 8
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F8.5"
  DESCRIPTION   = "Secondary open source anode current"
  UNIT          = "uA"
  VALID_MINIMUM = -0.5 
  VALID_MAXIMUM = 27.75
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 67
  NAME          = "d1Bias50"
  BYTES         = 5
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F5.2"
  DESCRIPTION   = "Open Source +40V Bias Oscillator Drive 
Current "
  UNIT          = "V"
  VALID_MINIMUM = -0.05
  VALID_MAXIMUM = 5.1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 68
  NAME          = "d1Bias70"
  BYTES         = 5
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F5.2"
  DESCRIPTION   = "Open Source primary Filament Bias Oscillator Drive Current"
  UNIT          = "V"
  VALID_MINIMUM = -0.05
  VALID_MAXIMUM = 5.1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 69
  NAME          = "d2Bias70"
  BYTES         = 5
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F5.2"
  DESCRIPTION   = "Open Source secondary Filament Bias 
Oscillator Drive Current"
  UNIT          = "V"
  VALID_MINIMUM = -0.05
  VALID_MAXIMUM = 5.1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 70
  NAME          = "dGround2"
  BYTES         = 5
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F5.2"
  DESCRIPTION   = "Ground reference voltage"
  UNIT          = "V"
  VALID_MINIMUM = -0.05
  VALID_MAXIMUM = 5.1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 71
  NAME          = "dAmString"
  BYTES         = 9
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F9.4"
  DESCRIPTION   = "AM Board Resistor Divider String Current"
  UNIT          = "V"
  VALID_MINIMUM = -645.  
  VALID_MAXIMUM = 5.1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 72
  NAME          = "dFbString"
  BYTES         = 9
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F9.4"
  DESCRIPTION   = "FB Board Resistor Divider String Current"
  UNIT          = "V"
  VALID_MINIMUM = -513.  
  VALID_MAXIMUM = 4.1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 73
  NAME          = "dBaCollector"
  BYTES         = 5
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F5.2"
  DESCRIPTION   = "BA  pressure  gage collector current"
  UNIT          = "V"
  VALID_MINIMUM = -0.05
  VALID_MAXIMUM = 5.1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 74
  NAME          = "dFbControl"
  BYTES         = 5
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F5.2"
  DESCRIPTION   = "-390V Regulator Control Voltage "
  UNIT          = "V"
  VALID_MINIMUM = -0.05
  VALID_MAXIMUM = 5.1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 75
  NAME          = "d3Emission"
  BYTES         = 8
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F8.5"
  DESCRIPTION   = "Emission Current of primary closed source filament"
  UNIT          = "uA"
  VALID_MINIMUM = -0.5 
  VALID_MAXIMUM = 25.75
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 76
  NAME          = "d4Emission"
  BYTES         = 8
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F8.5"
  DESCRIPTION   = "Emission Current of secondary closed source filament"
  UNIT          = "uA"
  VALID_MINIMUM = -0.5 
  VALID_MAXIMUM = 25.75
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 77
  NAME          = "dImon2"
  BYTES         = 8
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F8.6"
  DESCRIPTION   = "Input current"
  UNIT          = "A"
  VALID_MINIMUM = 0.0 
  VALID_MAXIMUM = 1.75
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 78
  NAME          = "dEb4_4"
  BYTES         = 5
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F5.2"
  DESCRIPTION   = "anode 3 current monitor in volts"
  UNIT          = "V"
  VALID_MINIMUM = -0.05
  VALID_MAXIMUM = 5.1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 79
  NAME          = "d3Current"
  BYTES         = 8
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F8.5"
  DESCRIPTION   = "Primary closed source filament current"
  UNIT          = "A"
  VALID_MINIMUM = -0.5 
  VALID_MAXIMUM = 1.5 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 80
  NAME          = "d4Current"
  BYTES         = 8
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F8.5"
  DESCRIPTION   = "Secondary closed source filament current"
  UNIT          = "A"
  VALID_MINIMUM = -0.5 
  VALID_MAXIMUM = 1.5 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 81
  NAME          = "d4Anode"
  BYTES         = 8
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F8.5"
  DESCRIPTION   = "Primary closed source anode current"
  UNIT          = "uA"
  VALID_MINIMUM = -0.1 
  VALID_MAXIMUM = 10.2 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 82
  NAME          = "d3Anode"
  BYTES         = 8
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F8.5"
  DESCRIPTION   = "Secondary closed source anode current"
  UNIT          = "uA"
  VALID_MINIMUM = -0.1 
  VALID_MAXIMUM = 10.2 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 83
  NAME          = "d3Bias50"
  BYTES         = 5
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F5.2"
  DESCRIPTION   = "Closed Source +40V Bias Oscillator Drive Current"
  UNIT          = "V"
  VALID_MINIMUM = -0.05
  VALID_MAXIMUM = 5.1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 84
  NAME          = "d3Bias70"
  BYTES         = 5
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F5.2"
  DESCRIPTION   = "Closed  Source primary Filament Bias Oscillator
                   Drive Current"
  UNIT          = "V"
  VALID_MINIMUM = -0.05
  VALID_MAXIMUM = 5.1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 85
  NAME          = "d4Bias70"
  BYTES         = 5
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F5.2"
  DESCRIPTION   = "Closed  Source secondary Filament Bias Oscillator
                   Drive Current"
  UNIT          = "V"
  VALID_MINIMUM = -0.05
  VALID_MAXIMUM = 5.1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 86
  NAME          = "dRfSupplyTemp"
  BYTES         = 9
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F9.6"
  DESCRIPTION   = "RF power supply temperature"
  UNIT          = "C"
  VALID_MINIMUM = 13.  
  VALID_MAXIMUM = 32.5 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 87
  NAME          = "dFbSupplyTemp"
  BYTES         = 9
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F9.6"
  DESCRIPTION   = "FB Board temperature"
  UNIT          = "C"
  VALID_MINIMUM = 13.  
  VALID_MAXIMUM = 32.5 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 88
  NAME          = "dEmSupplyTemp"
  BYTES         = 9
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F9.6"
  DESCRIPTION   = "EM Board temperature"
  UNIT          = "C"
  VALID_MINIMUM = 13.  
  VALID_MAXIMUM = 32.5 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 89
  NAME          = "dPlus5Fb"
  BYTES         = 5
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F5.2"
  DESCRIPTION   = "Thermister +5 reference voltage"
  UNIT          = "V"
  VALID_MINIMUM = -0.05
  VALID_MAXIMUM = 5.1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 90
  NAME          = "dBaGrid"
  BYTES         = 8
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F8.4"
  DESCRIPTION   = "BA pressure gage grid current"
  UNIT          = "uA"
  VALID_MINIMUM = -2.  
  VALID_MAXIMUM = 152.  
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 91
  NAME          = "dOl1"
  BYTES         = 8
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F8.5"
  DESCRIPTION   = "Open Lens 1 (CEU) Current"
  UNIT          = "uA"
  VALID_MINIMUM = -0.1 
  VALID_MAXIMUM = 6.8 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 92
  NAME          = "dOl2"
  BYTES         = 8
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F8.5"
  DESCRIPTION   = "Open Lens 2 (CEU) Current "
  UNIT          = "uA"
  VALID_MINIMUM = -0.1 
  VALID_MAXIMUM = 6.8 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 93
  NAME          = "dBaCurrent"
  BYTES         = 9
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F9.6"
  DESCRIPTION   = "BA pressure gage filament current"
  UNIT          = "A RMS"
  VALID_MINIMUM = -0.05
  VALID_MAXIMUM = 1.4 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 94
  NAME          = "dBaEmission"
  BYTES         = 8
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F8.4"
  DESCRIPTION   = "BA pressure gage emission current"
  UNIT          = "uA"
  VALID_MINIMUM = -1.6 
  VALID_MAXIMUM = 193.75
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 95
  NAME          = "dGround3"
  BYTES         = 5
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F5.2"
  DESCRIPTION   = "Ground reference voltage"
  UNIT          = "V"
  VALID_MINIMUM = -0.5 
  VALID_MAXIMUM = 5.1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 96
  NAME          = "dBaBias"
  BYTES         = 5
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F5.2"
  DESCRIPTION   = "BA pressure gage bias oscillator drive current"
  UNIT          = "V"
  VALID_MINIMUM = -0.5 
  VALID_MAXIMUM = 5.1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 97
  NAME          = "dRfAgc"
  BYTES         = 5
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F5.2"
  DESCRIPTION   = "RF automatic gain control monitor voltage"
  UNIT          = "V"
  VALID_MINIMUM = -0.5 
  VALID_MAXIMUM = 5.1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 98
  NAME          = "dMinus5_7"
  BYTES         = 7
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F7.4"
  DESCRIPTION   = "Monitor -5.7 Volt supply"
  UNIT          = "V"
  VALID_MINIMUM = -7.  
  VALID_MAXIMUM = 5.2 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 99
  NAME          = "dFcTemp"
  BYTES         = 9
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F9.6"
  DESCRIPTION   = "Flight computer board temperature"
  UNIT          = "C"
  VALID_MINIMUM = 18.5 
  VALID_MAXIMUM = 36.75
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 100
  NAME          = "dLvpStemp"
  BYTES         = 9
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F9.6"
  DESCRIPTION   = "Low voltage power supply frame temperature"
  UNIT          = "C"
  VALID_MINIMUM = 23.25
  VALID_MAXIMUM = 31.25
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 101
  NAME          = "dEm1Current"
  BYTES         = 7
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F7.4"
  DESCRIPTION   = "Electron multiplier 1 current monitor"
  UNIT          = "KV"
  VALID_MINIMUM = -0.5 
  VALID_MAXIMUM = 38.1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 102
  NAME          = "dEm2Current"
  BYTES         = 7
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F7.4"
  DESCRIPTION   = "Electron multiplier 2 current monitor"
  UNIT          = "KV"
  VALID_MINIMUM = -0.5 
  VALID_MAXIMUM = 38.1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 103
  NAME          = "dImon3"
  BYTES         = 8
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F8.6"
  DESCRIPTION   = "Input current"
  UNIT          = "A"
  VALID_MINIMUM = 0.0 
  VALID_MAXIMUM = 1.75
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 104
  NAME          = "dMultAna1"
  BYTES         = 5
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F5.2"
  DESCRIPTION   = "Pulse Amp 1 Analog Voltage Proportional to
                   Input Frequency "
  UNIT          = "uA"
  VALID_MINIMUM = -0.1 
  VALID_MAXIMUM = 10.2 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 105
  NAME          = "dMultAna2"
  BYTES         = 6
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F6.3"
  DESCRIPTION   = "Pulse Amp 2 Analog Voltage Proportional to 
                   Input Frequency "
  UNIT          = "uA"
  VALID_MINIMUM = -0.05
  VALID_MAXIMUM = 1.75
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 106
  NAME          = "dPlus5r"
  BYTES         = 5
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F5.2"
  DESCRIPTION   = "Monitor 5R voltage"
  UNIT          = "V"
  VALID_MINIMUM = -0.1 
  VALID_MAXIMUM = 10.2 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 107
  NAME          = "dThermPressInt"
  BYTES         = 5
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F5.2"
  DESCRIPTION   = "Internal BA pressure gage temperature"
  UNIT          = "V"
  VALID_MINIMUM = -0.05
  VALID_MAXIMUM = 5.1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 108
  NAME          = "dThermPressExt"
  BYTES         = 5
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F5.2"
  DESCRIPTION   = "External BA pressure gage temperature"
  UNIT          = "V"
  VALID_MINIMUM = -0.05
  VALID_MAXIMUM = 5.1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 109
  NAME          = "dPlus13"
  BYTES         = 7
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F7.4"
  DESCRIPTION   = "Monitor +13 voltage"
  UNIT          = "V"
  VALID_MINIMUM = -0.2 
  VALID_MAXIMUM = 14.75
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 110
  NAME          = "nIndex"
  BYTES         = 3
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I3"
  DESCRIPTION   = "AMUX index of first channel sampled for latest scan."
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 255 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 111
  NAME          = "dRfFreq"
  BYTES         = 5
  DATA_TYPE     = ASCII_REAL
  FORMAT        = "F5.3"
  DESCRIPTION   = "Frequency monitor"
  VALID_MINIMUM = 0.0 
  VALID_MAXIMUM = 0.22
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 112
  NAME          = "nCpuIdleCounter"
  BYTES         = 2
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I2"
  DESCRIPTION   = "Flight computer heartbeat counter"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 15 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 113
  NAME          = "bDisc0Reset"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Set to 1 on bootup to indicate last CPU reset was 
                   due to BIU discrete 0."
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 114
  NAME          = "bAllSysGo"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Master INMS error flag"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 115
  NAME          = "bAllSysGoLatched"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Latched version of master INMS error flag"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 116
  NAME          = "bExcNoHandler"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "unhandled exception occured "
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 117
  NAME          = "bSafeMode"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "not used"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 118
  NAME          = "bForcedSleep"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Indicates the instrument entered Sleep state due to 
                   detected high value on IMONs"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 119
  NAME          = "bBiuAutoInit"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "3-bit field that counts BIU auto-initializations." 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 120
  NAME          = "bGseTest"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "not used"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 121
  NAME          = "bSystemInitialized"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Indicates system initialization complete"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 122
  NAME          = "bSystemConfigured"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Indicates system configuration is complete"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 123
  NAME          = "bTgoDetect"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Readout of watchdog reset latch on FC board during bootup.
                   Usually set to 1 - unreliable indicator."
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 124
  NAME          = "bBiuReseToCc"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Indicates that a BIU reset has occured"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 125
  NAME          = "bIcError"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Set to 1 on bootup if reset is due to wayward 
                   instruction counter (jump to location 0)."
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 126
  NAME          = "bTgoToggle"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Toggled between 1 and 0 each time the Watchdog Reset
                   Task executes"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 127
  NAME          = "nSubModuleID"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I2"
  DESCRIPTION   = "Ada exception sub-module ID (CSU) 
                   0=SciPkt, 1= Usid, 4=UseqISR, 8=USIDLostSync"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 128
  NAME          = "nTrapFlag"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Ada exception/error type:
                   0=Trace_Trap, 1=Error_Trap, 2=Exception_Trap"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 3 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 129
  NAME          = "nModuleId"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I2"
  DESCRIPTION   = "Ada exception module ID (CSC) 
                   1=INMS_Exec, 2=INMS_Init, 3=AMux_IO, 4=DMux_IO,
                   5=DCon_IO, 6=CDS_IO, 7=Useq_IO, 8-10=spare,  
                   11=Filament Control, 12=Ion Source Select Control,
                   13=Ion Focus Control, 14=HV Focus Control,
                   15=Quad Rod Control, 16=Ion Det. Control,
                   17=Ion Pump Control, 18=Pressure Sensor Monitor,
                   19=Power Supply Monitor, 20=Micro-Sequencer Control"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 63 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 130
  NAME          = "bInmsBitFail"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Bootstrap Built-in-Test results"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 131
  NAME          = "bTmBuffOvrflw"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Set when the allotted memory buffer area for 
                   TM packets would have overflowed"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 132
  NAME          = "bAlfBoot"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Set when an ALF Boot is performed"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 133
  NAME          = "bAlfError"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Set when any BIU or ALF error is detected 
                   during an ALF Boot"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 134
  NAME          = "bBiuMemerror"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Set when background BIU verification processing 
                   detects a bad BIU memory location. No longer used."
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 135
  NAME          = "bOdbfrOverflow"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Output data buffer overflow. Not used"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 136
  NAME          = "bUseqOOffline"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Set when micro-sequencer output communication 
                   goes offline"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 137
  NAME          = "bUseqIOffline"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Set when micro-sequencer input communication 
                   goes offline"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 138
  NAME          = "bUseqError"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Set when any micro-sequencer error is detected"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 139
  NAME          = "b1750me"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Set when the 1750 Machine Error interrupt occurs 
                   and FT register ❮❯ 0400h"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 140
  NAME          = "bAmuxError"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "not used"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 141
  NAME          = "bCdsOOffline"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Set when BIU/CDS output communication goes offline"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 142
  NAME          = "bCdsIOffline"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Set when BIU/CDS input communication goes offline"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 143
  NAME          = "bCdsError"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "set if one or more of 1750ME, CDSoOffline or 
                   CDSiOffline are set"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 144
  NAME          = "bRteError"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = "Set any time bootstrap or RTE processing 
                   detects any of the following errors: 1750 BIT Fail; 
                   Any Memory Test fails; Unhandled Exceptions; 
                   Machine Error; TGO Reset or Wayward IC Reboot"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 145
  NAME          = "nMemChecksum"
  BYTES         = 1
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I1"
  DESCRIPTION   = " memory checksum error flag in FSW Version 8 or later
                    0(ok) 1(bad checksum)"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 1 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 146
  NAME          = "nStmCounter"
  BYTES         = 3
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I3"
  DESCRIPTION   = "Count of spacecraft tm mode message received 
                   (1 per second)"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 255 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 147
  NAME          = "nRtiCounter"
  BYTES         = 3
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I3"
  DESCRIPTION   = "Count of RTIs processed"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 255 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 148
  NAME          = "nMassTable"
  BYTES         = 3
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I3"
  DESCRIPTION   = "value of initial mass in current mass table"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 255 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 149
  NAME          = "nCmdSerno1"
  BYTES         = 3
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I3"
  DESCRIPTION   = "Serial Number and Time of the telecommand that is 
                   being acknowledged. Only two are maintained for 
                   each Packet"
  VALID_MINIMUM = 0 
  VALID_MAXIMUM = 255 
END_OBJECT    = FIELD 

OBJECT        = FIELD
  FIELD_NUMBER  = 150
  NAME          = "nSclkMilliSec"
  BYTES         = 9
  DATA_TYPE     = ASCII_INTEGER
  FORMAT        = "I9"
  DESCRIPTION   = "The milliseconds of the time of the 
                   packet. When used in combination with TSCLKTIME 
                   produces the exact spacecraft clock time the packet
                   was generated"
END_OBJECT    = FIELD