Download this file

PDS_VERSION_ID          = PDS3                                               
DATA_SET_ID             = "CO-S-INMS-3-L1A-U-V1.0"                           
RECORD_TYPE             = STREAM                                             
OBJECT                  = TEXT                                               
  PUBLICATION_DATE      = 2023-01-26                                         
  NOTE                  = "This file describes known errors or               
                           deficiencies in this archive volume."             
END_OBJECT              = TEXT                                               
END                                                                          
                                                                             
Users are encouraged to provide comments back to the PPI Node of the PDS     
if errors or omissions are found either in data or in documentation.         
Please send comments by e-mail or U.S. mail to the PPI Node PDS Operator:    
                                                                             
  Email             pds_operator@igpp.ucla.edu                               
                                                                             
  Telephone         (310) 206-6073                                           
                                                                             
  U.S. Mail         PDS Operator                                             
                    c/o Dr. Raymond Walker                                   
                    3845 Slichter Hall                                       
                    UCLA - IGPP                                              
                    Los Angeles, CA 90095-1567                               
                                                                             
                                                                             
                                                                             
                                                                             
Cumulative errata for this volume:                                           
                                                                             
Logical                                                                      
Volume     Error/Variance Description                                        
-------------------------------------------------------------------------    
                                                                             
1) New Static Standard Values                                                
                                                                             
     PRODUCT_TYPE    {DATA, GEOMETRY, CALIBRATION, DOCUMENT,                 
                     CATALOG, SOFTWARE ANCILLARY, BROWSE}                    
                                                                             
     HEADER object with HEADER_TYPE = TEXT.                                  
                                                                             
     Software change requests have been submitted to the PDS to adopt these  
     changes to the PDS standards but they have not yet been accepted.       
                                                                             
                                                                             
2) Other non-standard practices                                              
                                                                             
     The PDS standards do not specify where to store the required MD5        
     checksum file for a volume.  We have placed it in the root dircetory    
     of the volume with the file name "CHECKSUMS.TXT".  This may be          
     considered invalid by some verifiers.                                   
                                                                             
     PPI has created copies of the PDS catalog files in the EXTRAS/CATALOG   
     directory with a '.TXT' extension. While this makes the files accessible
     to users with the Windows operating system, it is not a standard        
     PDS practice.                                                           
                                                                             
     In order for PPI to be able to track all of the files associated with a 
     data set (data, documents, software ,etc.) and to be able to retrieve   
     them on-demand through our web pages, PPI must include keywords in      
     labels that some might find questionable. In particular, we associate   
     the same start/stop time, targets, mission phases, etc. with a document 
     that are used in the data set. Without these keywords, queries for      
     Cassini INMS data between times A and B would not return the documents  
     or software associated with the data.                                   
                                                                             
3) Known problems and the volumes they affect                                
                                                                             
2023-01-25: During the migration of these data to PDS4 it was discovered     
that corrections were necessary to some of the fields in the                 
DATA/L1A_STRUCT_05.FMT and L1A_STRUCT_06.FMT files. The corrections included 
changes to the number of bytes listed in a field. These corrections were made
in the PDS4 labels. The data remains unchanged. The PDS3 labels haven not    
been updated.                                                                
                                                                             
The following tables list the corrections to the number of bytes in the      
fields listed:                                                               
                                                                             
DATA/L1A_STRUCT_05.FMT                                                       
                                                                             
Field    PDS3 label   Corrected PDS4 label                                    
                                                                              
4           8              9                                                  
                                                                              
27          6              7                                                  
                                                                              
34          7              8                                                  
                                                                              
35          7              8                                                  
                                                                              
43          9             10                                                  
                                                                              
47          9             10                                                  
                                                                              
48          9             10                                                  
                                                                              
49          9             10                                                  
                                                                              
56          6              7                                                  
                                                                              
66          7              9                                                  
                                                                              
67          7              9                                                  
                                                                              
69          6              7                                                  
                                                                              
PDS3 L1A_STRUCT_06.FMT                                                        
                                                                              
Corrections to the number of bytes in the fields listed:                      
                                                                              
Field     PDS3 Label      Corrected PDS4 Label                                
                                                                              
28            6              7                                                
                                                                              
54            7              8                                                
                                                                              
57            7              8                                                
                                                                              
72            6              7                                                
                                                                              
78            9             10