Cumulative errata for this volume:
Logical
Volume Error/Variance Description
-------------------------------------------------------------------------
1) New Static Standard Values
PRODUCT_TYPE {DATA, GEOMETRY, CALIBRATION, DOCUMENT,
CATALOG, SOFTWARE ANCILLARY, BROWSE}
HEADER object with HEADER_TYPE = TEXT.
Software change requests have been submitted to the PDS to adopt these
changes to the PDS standards but they have not yet been accepted.
2) Other non-standard practices
The PDS standards do not specify where to store the required MD5
checksum file for a volume. We have placed it in the root dircetory
of the volume with the file name "CHECKSUMS.TXT". This may be
considered invalid by some verifiers.
PPI has created copies of the PDS catalog files in the EXTRAS/CATALOG
directory with a '.TXT' extension. While this makes the files accessible
to users with the Windows operating system, it is not a standard
PDS practice.
In order for PPI to be able to track all of the files associated with a
data set (data, documents, software ,etc.) and to be able to retrieve
them on-demand through our web pages, PPI must include keywords in
labels that some might find questionable. In particular, we associate
the same start/stop time, targets, mission phases, etc. with a document
that are used in the data set. Without these keywords, queries for
Cassini INMS data between times A and B would not return the documents
or software associated with the data.
3) Known problems and the volumes they affect
2023-01-25 - During migration to PDS4 it was noticed that The INMS Packet
data documentation says it includes five standard data product types,
outlined in the DS.Cat. However, of these five, only the Housekeeping (HKG)
Packets have been delivered to PDS and are included in this data set.
2023-01-25 - During the migration of these data to PDS4 it was discovered
that corrections were necessary to some of the fields in the
DATA/HKG_STRUCT_01.FMT file. The corrections included changes to the number
of bytes listed in a field and to the field format. In some cases the field
format was removed. These corrections were made in the PDS4 labels. The data
remains unchanged. The PDS3 labels haven not been updated.
The following table lists the corrections to the number of bytes in the
fields listed and format if present and corrected or removed:
Field PDS3 Label Corrected PDS4 Label
5 15, F.15.1 16
20 1 2
23 2, I2 3, I3
59 F7.4 removed
60 F8.5 removed
61 F8.6 removed
62 F5.2 removed
63 F8.3 removed
64, 65, 66 F8.5 removed
67,68, 69, 70 F5.2 removed
72 F9.4 removed
73, 74 F5.2 removed
75, 76 F8.5 removed
77 F8.6 removed
78 F5.2 removed
79, 80, 81, 82 F8.5 removed
85 F5.2 removed
86, 87, 88 F9.6 removed
89 F5.2 removed
90 F8.4 removed
91, 92 F8.5 removed
93 F9.6 removed
94 F8.4 removed
95, 96, 97 F5.2 removed
98 F7.4 removed
99, 100 F9.6 removed
101, 102 F7.4 removed
103 F8.6 removed
104 F5.2 removed
105 F6.3 removed
106, 107 F5.2 removed
109 F7.4 removed
129 1 2
|